background image

4

6

5

4

DIN 18650
BS 7036

EN 16005

3,50 m 

3 m

2,50 m

2 m

d max = 2,5 m

d max = 3 m

3,50 m 

3 m

2,50 m

2 m

max.
9 cm**

+

+

+

OR

WIDTH

Additional 
adjustments 
are possible by 
LCD or remote 
control 
(see p. 5)

Part of the detection field can be masked to reduce it. 

The arrow position determines the width of the detection field. 

INFRARED SAFETY FIELD

CLOSER

AWAY

If necessary, adjust the IR-curtain 

angle (from -7° to 4°, default 0°). 

Activate the visible* spots to verify 

the position of the IR-curtain.

ANGLE

SETUP 

TEST THE GOOD FUNCTIONING OF THE INSTALLATION BEFORE LEAVING THE PREMISES!

SETTINGS

* Visibility depends on external conditions. When spots are not visible, use MRSP to locate the curtains.

** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should 

always be smaller than 20 cm. The distance to the door leaf depends therefore on the thickness of the door leaf. 

The size of the detection field varies according to the 

mounting height and the settings of the sensor. 

The full door width must be covered.

OR

  

STANDARD

:

 standard  in- and outdoor installations

  

CRITICAL

 

ENVIRONMENT

critical installations due to surroundings or weather

  

SHOPPING

 

STREET

installations in narrow streets with pedestrian traffic

Mounting 
height

Detection 

width 

2.00 m

2.20 m

2.50 m

3.00 m

3.50 m

2.00 m

2.20 m

2.50 m

d max

d max

Choose one of the following presettings or adjust the sensor manually (see p.5):

Always verify the actual detection field width 

with a piece of paper and not MRSP, which 

detects the whole emitted field.

3.50 m 

3 m

2.50 m

2 m

d max = 2.5 m

3.50 m 

3 m

2.50 m

2 m

DOOR

SETUP 1 (QUICK)

SETUP 2 (ASSISTED)

OR

2 s

4 s

STEP OUT OF THE INFRARED FIELD!

reference picture

test of full door cycle +
reference picture

M

R

8

7

0

0 / F

A

0

0

3

61

M

0

☜☞

 I

X

IO

-DT

3 / 4

2

.8

6

3

8 / v

1 - 0

2

.1

6

Summary of Contents for MR8700

Page 1: ...b 9 IR curtain angle adjustment knob Opening safety sensor for automatic sliding doors according to EN 16005 and DIN 18650 including emergency exits ENGLISH User s Guide for product version 0400 and h...

Page 2: ...ALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed v...

Page 3: ...eight of the sensor In emergency exits the full door width must be covered GREEN BROWN YELLOW WHITE PINK GREY RED BLUE YE BK WH BK POWER SUPPLY OPENING INPUT SAFETY INPUT TEST OUTPUT OPENING INPUT FOR...

Page 4: ...ld always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settin...

Page 5: ...s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shop...

Page 6: ...ter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted...

Page 7: ...sk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be h...

Page 8: ...up to 3 optocouplers in series Detection current source OFF Open circuit remained voltage 500 mV EN 12978 EN ISO 13849 1 2008 PL d CAT 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 Aut...

Reviews: