MOUNTING THE PROFILE

POSITIONING THE MODULES

WIRING

GREEN

BROWN

YELLOW

WHITE

BLACK

PINK

GREY

VIOLET

RED**

BLUE**

POWER SUPPLY

STOP IMPULSE
Opening side of door

REOPENING IMPULSE
Closing side of door

TEST OUTPUT***

The transmitter (TX) should be placed next to 
the door edges that need to be protected.

The angle adjustment clip should be next to 
the transmitter.

Turn the module if necessary.

When a module needs to be turned:

1. detach the clips
2. turn them by 180°
3. reattach

NO POWER

NO DETECTION

DETECTION

The module connected to the door controller 
becomes the 

MASTER

.

Plug the SLAVE 
CABLE between 
the modules in 
one of the two 
placements. 

Mount the profi les as close as possible to the closing edge. Leave 2 cm 
for the black end caps. Take the position of the white clips into account 
before drilling and fastening the screws.

*  Output status when sensor is operational 
**   For compliance with EN 16005 and DIN 18650, connection to door controller test output is required.
*** If door controller is not tested: conncect BLUE to 0 V and RED to +12 V - 30 V DC.

To loosen the modules, please use 