Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
F5
Safety devices test
0 =Deactivated (Default)
1 = CX
2 = CY
3 = CX+CY
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6
Hold-to-run
0 =Deactivated (Default)
1 = Activated
Obstacle with motor stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function activates with: closed boom, open boom or after a complete stop.
F9
Obstacle with motor stopped
0 =Deactivated (Default)
1 = Activated
Open warning light
Barrier status warning. Device connected to the 10-5 output.
F10
Open warning light
0 = Warning light on (default) - The light stays on when the boom is moving or open.
1 = Warning light flashing - The warning light flashes every half a second when the boom is
opening and remains on when the boom is open. The light flashes every second when the
boom is closing, and remains off when the boom is closed.
Sensor type
Set the type of control device.
F14
Sensor type
0 = Transponder
1 = Keypad (Default)
Flashing rope light
Choose how you would like the barrier status to be signalled using the rope light flash settings.
F15
Flashing rope light
0 = The rope light flashes when the boom is moving (Default).
1 = The rope light flashes when the boom is moving and when closed.
Light E1
Choose the type of device connected to the output.
F18
Light E1
0 =Flashing beacon (Default)
1 = Cycle light
This parameter does not appear if there [Automatic Close] function is deactivated.
2 = Courtesy light.
The lighting device remains on for the time set for the [Courtesy time] function.