VAS101
Installation
The power supplier must ALWAYS be installed horizontally. The
device can be installed on a DIN rail (EN 50022) in an appropriate
electric panel.
NOTE. Proper ventilation is required if the power supplier is in-
stalled in a metal container.
Technical features
Type
VAS101
Power supply [V AC]
230
Max current demand [A AC]
0,2
Max energy dissipation [W]
10
Nominal power supply [V DC]
18
Nominal current demand [A DC]
1 for 1’
Nominal current demand [A DC]
0.5 for 3’
Storage temperature [°C]
-25 ÷ +70
Operating temperature [°C]
0 ÷ +35
IP Rating [IP]
30
Features
A
Terminal board
a
~
Mains
~
Terminal board
–
+
Power supply 18 VDC (*)
(*) The appliance is electronically protected against overloads
and short circuits.