Size

94

426

586

358

58

644

416

Usage limitations

 For leaves longer than 2.5 m, install an electric lock.

MODELS

FROG-PM4

FROG-PM6

Gate-leaf length (m)

5.5

4.5

3.5

2.5

7

6

5

4

Gate-leaf weight (Kg)

700

900

1100

1400

550

650

800

1000

Technical data

MODELS

FROG-PM4

FROG-PM6

Power supply (V - 50/60 Hz)

230 AC

230 AC

Motor power supply (V)

230 AC

230 AC

Power (W)

500

500

Capacitor (μF)

16

16

Current draw (mA)

2,1

2,1

Operating temperature (°C)

-20 ÷ +55

-20 ÷ +55

Torque (Nm)

800

800

Opening time at 90° (s)

30

45

Cycles/hour

10

6

Motor thermal protection (°C)

150

150

Protection rating (IP)

67

67

Weight (kg)

38

38

Cable types and minimum thicknesses

Cable length (m)

up to 20

from 20 to 30

Motor power supply 230 V AC

4G x 1.5 mm2

4G x 2.5 mm2

 When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when operating indoors, use H05VV-F cables compliant 

with 60227 IEC 53 (IEC). For power supplies up to 48 V, you can use FROR 20-22 II cables compliant with EN 50267-2-1 (CEI).

 If the cable lengths differ from those specified in the table, define the cable cross-sections according to the actual power draw of the connected devices 

and in line with regulation CEI EN 60204-1.

 For multiple, sequential loads along the same line, recalculate the values in the table according to the actual power draw and distances. For information 

on connecting products not covered in this manual, please see the documentation accompanying the products themselves.

 To connect the encoder, use a FROR 300/500 V shielded cable (3 x 0.5 mm²).

Summary of Contents for FROG PLUS

Page 1: ...Swing gate operator FROG PLUS FROG PM4 FROG PM6 INSTALLATION MANUAL FA01648 EN EN English...

Page 2: ......

Page 3: ...talogue or on the website www came com Make sure the mains power supply is disconnected during all installation procedures Check that the temperature ranges given are suitable for the installation sit...

Page 4: ...ised standards and the essential requirements of the Machinery Directive 2006 42 EC Any residual risks must be indicated clearly with proper signage affixed in visible areas and explained to end users...

Page 5: ...kg in weight FROG PM6 Underground irreversible 230 V gearmotor with encoder and adjustable leaf stop during closing for swing gates with leaves up to 7 m in length and 550 kg in weight Intended use C...

Page 6: ...38 38 Cable types and minimum thicknesses Cable length m up to 20 from 20 to 30 Motor power supply 230 V AC 4G x 1 5 mm2 4G x 2 5 mm2 When operating at 230 V and outdoors use H05RN F cables compliant...

Page 7: ...d the most suitable solution The drawings refer to the right side gearmotor Preliminary operations The preliminary operations for installation concern the foundation box installation and the release d...

Page 8: ...mining the travel end points with mechanical limit switches Manually open the leaf to the desired point The leaf maximum opening is 110 Unscrew the opening limit switch point adjustment screw until it...

Page 9: ...control panel disconnect the mains power supply and remove the batteries if any Provide IP67 junction boxes with terminal blocks for connections 1 Blue cable 2 Brown cable 3 Black cable 4 Yellow gree...

Page 10: ...tion of the original instructions FINAL OPERATIONS OUTWARDS OPENING The only operation that is different from the standard installation is described below Setting up the gearmotor Insert the closing l...

Page 11: ...Page 11 Manual FA01648 EN 10 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...

Page 12: ...s of this manual may be changed at any time and without notice Translation of the original instructions AFFIX THE PRODUCT LABEL FROM THE BOX HERE CAME S p A Via Martiri della Libert 15 31030 Dosson di...

Reviews: