CAME ENTROTEC ED5 Manual Download Page 2

F

GENERAL PRECAUTIONS

Read the instructions carefully before beginning the 
installation and carry out the procedures as specifi ed by the 
manufacturer. • Installation, programming, commissioning 
and maintenance must only be carried out by qualifi ed, 
expert technicians and in full compliance with the applicable 
law. • Before carrying out any cleaning or maintenance, 
disconnect the device from the power supply. • Only use this 
product for its intended purpose. Any other use is hazardous. 
• Came S.p.A. is not liable for any damage caused by 
improper, erroneous or unreasonable use. • Do not obstruct 
the ventilation or heat dissipation vents or slots. • Il prodotto 
è conforme alle direttive applicabili, vigenti al momento della 
fabbricazione.

DESCRIPTION

Intercom internal audio receiver.

Technical data

Type

ED5

Volume

84dB SPL Max (at 1 metre)

Operating Voltage

12-15VDC (13.8V Nominal)

Power

~0.01W Idle, 2.6W Active

Connections

11 Way Screw Terminals

Dimensions

(WxHxD) 96 x 206 x 49mm 

(approx. not including 

cable)

INSTALLING

Open the device by pressing on the tab at the bottom and 
separate the shell from the bottom of the device. 

A

Fasten the bottom of the device to the box on the wall. 

B C D

 Avoid overtightening the screws.

 The box must be installed at an appropriate height for 

the user.

Once all connections have been made, reattach the shell to the 
bottom of the device. 

E

HANDSET CONNECTION

F

 Control board

 Terminal block

Preferred colour coding for 
wiring handsets

Function

DR

White/Blue

DR 1

Door release

VT

Blue/White

VT 2

12VDC input

0V

White/Orange

0V 3

Common

BZ

Orange/White

BZ 4

Ringtone signal

S2

White/Green

S2 5

Audio from handset 
mic.

S1

Green/White

S1 6

Audio to handset spk.

DS

White/Brown

DS 7

Door status LED

CB

-

-

Call back

EX

-

-

External sounder

 Ringtone volume switch

 Timer switch

Reviews: