5.2 Tools and materials
Make sure all tools and materials necessary are within reach to install the edge in maximum safety, according to regulations in
force. The following figure illustrates the minimum equipment for the installer.
5.1 Preliminary checks
It is necessary to verify that the sensitive edge’s fixing point is on a suitable surface prior to installation.
5.3 Cable list
5 Installation
Prepare ducts and tubes suitable for the passage of electrical wiring so as to guarantee protection against mechanical dama-
ge. Type of cables recommended:
Connection
Cable type and minimum section Maximum length allowed
A - Output contacts C - N.C.
FROR (flexible) 2 x 0.5 mm
2
30 m*
B - Output contacts C - N.C. - N.O.
FROR (flexible) 3 x 0.5 mm
2
30 m*
C - Output contacts C - N.C. + Power supply 12-24V
FROR (flexible) 4 x 0.5 mm
2
30 m*
Warning: improper installation may cause serious damage. Follow all installation instructions.
*A longer cable may be used as long as the section is greater.