
23
- Manual
FA01413-EN
- 02/2020 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
Download the LIST OF REGISTERED USERS form from the docs.came.com portal by typing in L20180423.
U1
New user
1 = Step-by-step
2 = Sequential
3 = Open
4 = Partial opening
Choose the function to be assigned to the user.
Press ENTER to confirm.
You will be asked to enter your user code.
Send the code from the control device.
Repeat the procedure to add other users.
Remove user
Remove one of the registered users.
U2
Remove user
Use the arrows to choose the number associated with the user you want to remove.
Alternatively, the control device associated with the user you want to remove can be
activated.
Press ENTER to confirm.
“CLr” will appear to confirm deletion.
Remove all
Remove all registered users.
U3
Remove all
OFF (Default)
ON
Radio decoding
Choose the type of radio coding for the transmitters enabled to control the operator.
If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved
previously will be deleted.
U4
Radio decoding
1 = All decoding (default)
2 = Rolling code
3 = TW key block
Motor type
Set the type of gearmotor installed.
A1
Motor type
1 = BX604
2 = BX608
Parameter reset
Restore factory settings except for the functions: [Radio decoding], [Motor type] and the settings related to travel calibration.
A4
Parameter reset
OFF (Default)
ON