Set the device switch to ON.
E
Turn the rod (A) CLOCKWISE to set the
limit-switch opening point. The device will
beep and the green limit-switch opening
LED (Ra) will switch on.
F
Close the gate manually.
Turn the rod (C) ANTICLOCKWISE to set the
limit-switch closing point. The device will
beep and the red limit-switch closing LED
(Rc) will switch on.
G
Once the adjustments have been
made, turn the device OFF. Disconnect
the 9-pole terminal block from the device
and reconnect it to the gearmotor board
assembly.
Attach the protective covers.
Procedure for 230V gearmotors
Perform these operations on both
gearmotors.
Release the gearmotor.
H
Manually open the leaf to the desired
point.
Remove the protective covers to access
the gearmotor terminal block and the limit-
switch adjustment rods.
I
Connect the gearmotor terminal block
(W-V-U) to the limit-switch adjustment
device using the 3-pole terminal block and
a FROR cable 3x1 mm2 (not supplied).
Before connecting the gearmotor
to the adjustment device, disconnect it
from the control panel or disconnect the
power supply.
J
Set the device switch to ON.
K
Turn the rod (A) CLOCKWISE to set the
limit-switch opening point. The device will
beep and the green limit-switch opening
LED (Ra) will switch on.
L
Close the gate manually.
Turn the rod (C) ANTICLOCKWISE to set the
limit-switch closing point. The device will
beep and the red limit-switch closing LED
(Rc) will switch on.
M
Once the adjustments have been made,
turn the device OFF and disconnect the
gearmotor terminal block from the device.
Attach the protective covers.
For outward-opening systems,
points E, F, K and L above are diff erent.
To determine the limit-switch opening
point, turn the rod (C) ANTICLOCKWISE.
The red LED (Rc) will switch on. To
determine the limit-switch closing point,
turn the rod (A) CLOCKWISE. The green
LED (Ra) will switch on.
The contents of this manual may be
changed at any time and without notice.
Summary of Contents for 801XC-0180
Page 1: ...801XC 0180 FA01794M4A IT Italiano EN English FR Français RU Pусский ...
Page 2: ...Pag 2 Manuale FA01794M4A 04 2022 CAME S p A 9 V W V U M N Rc Rc Ra Ra E Ra Rc ON OFF ...
Page 3: ...Pag 3 Manuale FA01794M4A 04 2022 CAME S p A 9 V A ...
Page 4: ...Pag 4 Manuale FA01794M4A 04 2022 CAME S p A ATS 24V B ...
Page 5: ...Pag 5 Manuale FA01794M4A 04 2022 CAME S p A ATS 24V C ...
Page 6: ...Pag 6 Manuale FA01794M4A 04 2022 CAME S p A W V U Ra Rc ON OFF ATS 24V D ...
Page 7: ...Pag 7 Manuale FA01794M4A 04 2022 CAME S p A W V U ON OFF Ra W V U ON OFF Ra Rc STOP ATS 24V E ...
Page 9: ...Pag 9 Manuale FA01794M4A 04 2022 CAME S p A ATS 24V G ...
Page 10: ...Pag 10 Manuale FA01794M4A 04 2022 CAME S p A ATS 230V H ...
Page 11: ...Pag 11 Manuale FA01794M4A 04 2022 CAME S p A ATS 230V W V U W V U W V U I ...
Page 12: ...Pag 12 Manuale FA01794M4A 04 2022 CAME S p A W V U Ra Rc ON OFF ATS 230V J ...
Page 15: ...Pag 15 Manuale FA01794M4A 04 2022 CAME S p A ATS 230V M ...