Additional light connection output (Contact rated for: 24 V AC - 25 W max):
- flashing light dome, which flashes during the barrier's opening and closing phases.
- cycle or courtesy light, which is a freely positionable outdoor light for enhanced lighting
in the driveway.
Cycle light, which stays on from the moment the boom starts opening until it is fully
closed (including the automatic closing time).
Courtesy light, which stays on for a settable time between 60 and 180 seconds, see
function F18.
Signaling devices
Luminous cord (Contact rated for: 24 V AC - 32 W max).
If flashes during the boom's opening and closing phases, see function F 15.
Barrier open signal-output (Contact rated for: 24 V AC - 3 W max).
It signals the status of the barrier, (function F10).
Configure contact (NC) CX or CY, input for safety devices,
such as photocells, that comply withEN 12978 provisions.
CX input (function F 2) or CY (function F 3).
C1 reopening while closing. When the boom is closing, opening
the contact causes its movement to invert until fully opened;
C4 obstruction wait. Stoppingthe boom, if it is moving, with
resumption of movement after the obstruction is removed.
C5 immediate closing. Closing the boom after a vehicle has
passed through the operating area of the safety devices.
C9 immediate closing with obstruction wait when closing.
Closing the boom after a vehicle has passed through the
operating area of the safety devices.
During the closing phase, the devices also perform the C4
obstruction wait function.
If unused, contacts CX and CY should be deactivated during
programming.
Safety devices
Photocells
DELTA
Photocells
DELTA-S
Photocells
DIR
Summary of Contents for 001G4040EZT
Page 1: ...English EN Русский RU Italiano IT Français FR FA00583M04 BARRIERE AUTOMATICHE ...
Page 33: ...English EN INSTALLATION MANUAL G4040EZT AUTOMATIC BARRIERS FA00583 EN ...
Page 65: ...Français FR MANUEL D INSTALLATION G4040EZT BARRIÈRES AUTOMATIQUES FA00583 FR ...
Page 97: ...Русский RU ИНСТРУКЦИЯ ПО МОНТАЖУ G4040EZT АВТОМАТИЧЕСКИЕ ДОРОЖНЫЕ ШЛАГБАУМЫ FA00583 RU ...