Features
Terminal boards A
~
Mains
~
Terminal boards B
5
6
–
Power supply 17,5 VDC (*)
+
to entry panel
5
–
12V supply voltage audio
21 +
entry system accessories
8
Call common 1
8A
Call common 2
22
Stair light actuator output (VLS/101)
11
Audio to monitor
12
Audio to entry panel
23
Auxiliary door lock release button
14
Entry panel activation
13 +
Power supply 12 VDC (*)
16 –
to electrical door lock
Terminal boards C
5 –
Power supply 17,5 VDC
6 +
to monitor and accessories
8
Audio to monitor
9
Audio to entry panel
Terminal boards D
Coaxial cable connection
3
Video signal
4
Video signal shield
7
Call no. 1
Coaxial cable connection
3
Video signal
4
Video signal shield
7
Call no. 1
(*) The appliance is electronically protected against overloads
and short circuits.
Adjustments
TV:
activation time of the system (30÷90 s).
: solenoid door lock activation time (1÷15 s).
SW (Selection of second ring tone)
Doorbell
Second additional entry
panel