FUNCTION CODE
⑦
Setting the keypad locking time, resulting from repeatedly
entering non-existent codes (default 10 s)
- Key in the LOCKING TIME from
①
to
⑥⑤
seconds.
FUNCTION CODE
⑧
Setting monostable or bistable mode of relays (default mon-
ostable)
- Key in the desired SERVICE/RELAY.
①
= activation of relay 1,
②
= activation of relay 2,
③
= activation of relay 1 in Tradesman operation.
- Key in TYPE OF ACTIVATION
= BISTABLE
①
= MONOSTABLE
- Repeat the procedure to set another service/relay.
FUNCTION CODE
⑨
Enabling/disabling alarm and bell (default disabled)
- Key in the mode:
= DISABLED
①
= ALARM ENABLED
②
= BELL ENABLED
NOTE. Enabling the alarm or the bell disables the settings
of relay 2.
FUNCTION CODE
①
Reset alarm
FUNCTION CODE
①
①
Programming input I1 (default command relay 1).
- Key in:
= Command relay 1
①
= Enable Tradesman
②
= Command green LED A
③
= Disabled
FUNCTION CODE
①
②
Enabling/disabling keypad (default enabled).
- Key in:
= Disabled
①
= Enabled
FUNCTION CODE
①
③
Programming green LED A
- Key in:
= Disabled
①
= Access by pressing any button
Note. Programming is not possible if the LED is already
associated to input I1 (see function 11).
Reset procedure
- Cut power to the device.
- Repower the device again (green LED C off).
- Key in the RESET CODE within 1 min from switch-on.
Note. The stored user codes and the number of figures pro-
grammed are retained.