6. WIRING THE CM-221

1. Connection to a Maglock

Connect the ground (-) of the maglock to the ground (-) of the VDC power supply. Next connect the (+) of the maglock to the 
(N.C.) of the manual pushbutton. Connect the common (com) of the manual pushbutton to the PIR sensor purple wire (normally 
closed.) Jumper the PIR sensor blue (common) and red (power +) wires and then connect them to the (+) positive terminal of the 
DC power supply. Wire the PIR sensor black (-) wire to the negative (-) terminal of the DC power supply.

+

CX‐PS13 Power Supply

12 or 24 VDC

B‐  B+  DC‐ DC+ AC  AC

CX‐TR Transformer

12, 16 or 24 VAC

120 VAC

Jumper must be OFF, the two 

pins are not shorted 

CAUTION: All 

unused wire 

conductors 

should be 

individually 

isolated and 

taped.

CM‐221M Touchless Switch with manual pushbutton wired to maglock 

Maglock

+

7   6   5   4   3   2   1

7 Wire colored wire harness

#

Color Function

1

Red

12 to 24 VDC

2

Black

0 VDC (Ground)

3

Yellow Green LED controlled by external mode.

4

White Red LED, controlled by external mode.

5

Green Relay: Normally Open

6

Blue

Relay: Common

7

Purple Relay: Normally Closed

N.O.

N.C.

COM

3 Wire colored wire harness

#

Color Function

1

Red

Common

2

Black

Normally Open

3

White Normally Closed

WHT

RED

BLK