Page 3 of 6
CM-221M TOUCHLESS EXIT SWITCH
INSTALLATION INSTRUCTIONS
6. WIRING THE CM-221
1. Connection to a Maglock
Connect the ground (-) of the maglock to the ground (-) of the VDC power supply. Next connect the (+) of the maglock to the
(N.C.) of the manual pushbutton. Connect the common (com) of the manual pushbutton to the PIR sensor purple wire (normally
closed.) Jumper the PIR sensor blue (common) and red (power +) wires and then connect them to the (+) positive terminal of the
DC power supply. Wire the PIR sensor black (-) wire to the negative (-) terminal of the DC power supply.
‐
+
CX‐PS13 Power Supply
12 or 24 VDC
B‐ B+ DC‐ DC+ AC AC
CX‐TR Transformer
12, 16 or 24 VAC
120 VAC
Jumper must be OFF, the two
pins are not shorted
CAUTION: All
unused wire
conductors
should be
individually
isolated and
taped.
CM‐221M Touchless Switch with manual pushbutton wired to maglock
Maglock
+
‐
7 6 5 4 3 2 1
7 Wire colored wire harness
#
Color Function
1
Red
12 to 24 VDC
2
Black
0 VDC (Ground)
3
Yellow Green LED controlled by external mode.
4
White Red LED, controlled by external mode.
5
Green Relay: Normally Open
6
Blue
Relay: Common
7
Purple Relay: Normally Closed
N.O.
N.C.
COM
3 Wire colored wire harness
#
Color Function
1
Red
Common
2
Black
Normally Open
3
White Normally Closed
WHT
RED