CAMDEN CX-12 Installation Instructions Manual Download Page 9

FILENAME:

CX_12 Diagram 3b.vsd

DRAWING No: DRG-CX12-03b

CX-12 Application Diagram for Apt. (with Vestibule Keyswitch)

SCALE:  NONE

DRAWN BY: DGW

REVISED: 

DATE:  11/16/09

Camden Manufacturing

5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7

12 - 24 V

AC/DC

Power

Optional

Vestibule mounted

Convenience Switch

(Only active when

Lock relay energized)

Switch 

opens

door

Electric Strike

Door Operator

MOV

Wire MOV 

(supplied) 

directly to strike 

or magnet

Power

for Strike

Apartment

Interphone

Panel

(DRY contact)

Unlocks

door only

Interior Switch

Unlocks 

and

opens door

1

5

2

3

4

6

7

8

9 10 11 12 13 14 15 16

RL1

LED

RL2

LED

DOR

RL1

DOO

RL2

DOR

RL2

Off / On

1

2

CX-12

NOTE:  Use this diagram 
in case the Interphone 
outputs a 

dry contact

instead of a powered 
signal.

Vestibule

Keyswitch

(Optional)

Summary of Contents for CX-12

Page 1: ...lock will remain energized while the DRY 2 input allows a wall switch to open the door An input on DRY 1 will always unlock and open the door SEE DIAGRAM 02b Select Relay 2 Maintained if you are conne...

Page 2: ...Typically the access panel or time clock will be wet powered therefore connect to WET 1 Terminals 9 10 The exterior activating switch is wired to DRY 2 Terminals 15 16 This input signals the door oper...

Page 3: ...t Section 5_________________ Technical Data Model CX 12 Size 3 x 2 x Mounting Velcro or double sided tape Enclosure Protective paper sleeve Operating voltage 12 24 Volts AC DC Current Draw 18 mA stand...

Page 4: ......

Page 5: ...nufacturing 5502 Timberlea Blvd Mississauga Ontario L4W 2T7 12 24 V AC DC Power Dry Input ie Push Switch Wet Input ie Radio Receiver Electric Strike Door Operator MOV Wire MOV supplied directly to str...

Page 6: ...rlea Blvd Mississauga Ontario L4W 2T7 12 24 V AC DC Power Electric Strike Door Operator MOV Wire MOV supplied directly to strike or magnet Power for Strike Fire Alarm Panel Shown with maintained power...

Page 7: ...Electric Strike Door Operator MOV Wire MOV supplied directly to strike or magnet Power for Strike Exterior Switch in circuit only while Lock Relay is active If Mag lock used wire to Terminals 4 5 1 5...

Page 8: ...12 24 V AC DC Power Optional Vestibule mounted Convenience Switch Only active when Lock relay energized Switch opens door Electric Strike Door Operator MOV Wire MOV supplied directly to strike or mag...

Page 9: ...ence Switch Only active when Lock relay energized Switch opens door Electric Strike Door Operator MOV Wire MOV supplied directly to strike or magnet Power for Strike Apartment Interphone Panel DRY con...

Page 10: ...SED DATE 11 16 09 Camden Door Controls 5502 Timberlea Blvd Mississauga Ontario L4W 2T7 12 24 V AC DC Power Door 2 Push Switch Door 2 Operator Door 1 Operator Wet output ie RF receiver optional Wet out...

Reviews: