Page 2 of 5
CM-550SK V3 WATERPROOF KEYPAD
INSTALLATION INSTRUCTIONS
Stand-Alone Operation (PIN Data stored in the CM-550SK V3)
Single Door Stand-Alone
03 1 # Stand-Alone Mode
ID#
This refers to the memory address of where the Card or PIN
data is stored. It is not the PIN to unlock the door.
Keep track of where data is stored to easily edit or delete any
individual record.
Add a PIN (To a Specific ID#)
11 ID# (4-Digit PIN or Card) #
Multiple Entries 11(ID) #, (User PIN or Card) #, (ID) #,
(User PIN or Card) #
This will allow you to pick a unique ID # (storage location) to
add the PIN to.
Default Master Code
Power up while holding the
* key. The LED will turn orange
and you will hear a double beep.
This will only default the Master Code for programming. All
other data will not be affected.
Restore Configuration to Factory Defaults
For assistance call the Camden Technical Support line at
1-905-366-3377.
Delete All Users PIN Data
Press
20 0000 # Deletes All User Card/PIN data.
Enter Programming Mode
Press
the star (*) key for 2 seconds until it beeps then press
8 8 8 8 8 8 #.
The LED will now be flashing Red.
Exit Programming Mode
Press
the star key (*) to get a solid Red LED.
Change Admin Password
00 New 6-digit code #, New 6-digit code # (must be 6 digits).
The keypad cannot be configured until the Master Code
has been changed from its default to any other 6-digit PIN.
Operation Status
Indicator light
Buzzer
Standby mode
Red
Successful operation
Green
A long beep
Operation incorrect
3 short beeps
When admin card enter
2 short beeps
When admin card exit
A long beep
Press digit key
A short beep
Press * key
A long beep
Inputting opening door PIN
Red slow flash
Both read card and input PIN Mode,
after reading the card
Red slow flash
Multi-card reading open the door, when the card
reading is not over yet
Red slow flash
Enter the first zone admin main menu
Red slow flash
Enter the first zone setting status
Orange
The first unlock
Green
Alarm
Red quick flash
Alarm Sound
Indicator light and buzzer prompt