9. USER OPERATION

9.1 Entry PIN Mode 
- Press PIN (4 to 6 digits), #, lock will be unlocked.
9.2 Relay Mode 
- Relay setting-pulse mode.
- Every time a valid card/tag read or PIN input, the relay 
  will operate, for the pre-set relay pulse time.
- Relay setting-toggle mode.
- Every time a valid PIN is entered, the relay changes state,  
  which will not turn back until a valid PIN is entered again.

9.3 Modify User PIN (no need to enter programming) 
- Press ID number #, old PIN #, new PIN #, new PIN #

10. ALARM FUNCTION

10.1 Anti-Tamper Alarm 
- If the device is disassembled  illegally, the buzzer and the  
  external alarm will operate.

10.2 Door Contact Alarm  
-  When connected with door contact: if the door is opened 

illegally, the buzzer and the external alarm will operate.

10.3 The Anti-Duress Alarm 

 
- Input 8-digit PIN and press #
- Corresponding lock will open. At the same time, the external 
  alarm will operate, but the device buzzer will not operate.
10.4 Remove Alarm 
-  Input master code, then alarm will be removed. The alarm 

will time out automatically after 1 min.

11. MULTI-WORKING MODE

There are 3 working modes with this device.

1. Wiegand Reader.
2. Standalone for single door.
3. Anti-passback for single door.

The factory default is Standalone for single door (we can 
change the default model according to customer order). User 
can modify the working mode when the device reset to factory 
default, the setting is still valid. 

11.1 Wiegand Reader Mode 
In this mode, the access control works as a reader, connected 
with the common access controller. 
It has the following function:

•  Modify master pin
•  Set facility code
•  Set the keypad transmission format
•  Set optional setting
•  Anti-Tamper alarm

When LED level is low, indicator light (LED) will turn into green, 
after 30 seconds or LED level riding, LED will go back to normal.

When BZ level is low, the buzzer will beep, after 30 seconds or 
BZ level rising, the buzzer will go back to normal.

When used as the reader, the keypad transmits in Wiegand 
format, the output data is shown by the low level of D0&D1 wire:

D0: Low level means 0, green wire 
D1: Low level means 1, white wire

The pulse width of low level is 100uS, bit period is 1.6mS. 

Keypad transmission can be set in the following 3 modes 
(modes can be set by user).

Model 0: Virtual Card Number

The reader will transmit the PIN data when it receives the last 
key (#) press after PIN code

Format: Decimal card number wih 10 digits, Facility code (1st-
4th digit) + PIN Code (5-10th digit)

Facility code is any digit between 0-15, PIN code is 4-6 digits.

Example: facility code: 15 
PIN code: 999999 
Press 999999#, then output format will be 0015999999

Model 1: 4 Bit

The output data is provided in the following format after every 
key is pressed:

Key

Output in Hex

Output in Binary

0

0

0000

1

1

0001

2

2

0010

3

3

0011

4

4

0100

5

5

0101

6

6

0110

7

7

0111

8

8

1000

9

9

1001

*

A

1010

#

B

1011

Summary of Contents for CM-550SK-V2

Page 1: ... It is suitable for mounting either indoors or outdoors in harsh environments It is housed in a strong sturdy and vandal proof Zinc Alloy electroplated case The electronics are fully potted so the CM 550SK is waterproof and conforms to IP68 The CM 550SK supports up to 2000 users with a 4 6 digit PIN These features make CM 550SK an ideal choice for door access for commercial and industrial applicat...

Page 2: ...he cable hole 6 Attach the keypad to the back cover 5 WIRING No Marks Colour Description 1 BELL_A Pink Doorbell button 2 BELL_B Pink Doorbell button 3 D0 Green Wiegand output D0 4 D1 White Wiegand output D1 5 ALARM Gray Alarm 6 OPEN Yellow Request to Open BUZ 7 D_IN Brown Door Contact LED 8 DC Red Power IN 9 GND Black Ground 10 NO Blue Relay NO 11 COM Purple Relay Com 12 NC Orange Relay NC 6 SOUND...

Page 3: ...e 05 Anti duress PIN Anti duress PIN 07 0000 Delete All Users 51 Master open 7 2 User Setting Standby Master Code Menu Setting Remarks Functions Red Flash Red Red Orange Master Code 11 User ID number PIN Users can be added continuously without exiting programming mode To add PIN users 12 User ID Number Users can be added continuously without exiting programming mode To Delete Users 13 2 Default 2 ...

Page 4: ... Red Red Orange Master Code 41 0 Buzzer is turned off except while in programming mode 1 Default 1 Buzzer will sound during key presses 42 0 Disable keypad backlighting 1 Enable keypad backlighting 43 0 LED Light Disable while in stand by 1 Default 1 LED flashes while in stand by Notes 1 Master code must be 6 8 digits 2 Anti duress PIN must be 8 digits 3 User PIN is 4 6 digits 4 The user ID number...

Page 5: ...t while in programming mode Press master code factory default 999999 Press 51 Note The relay will operate for the relay on time 8 5 Users Setting Note ID number is 1 4 digits the range is 1 2000 1 01 001 0001 all these mean ID number 1 Use ID number and PIN to add user Press 11 ID number PIN ID number PIN Note The PIN is any 4 6 digits exept 1234 which is reserved 8 6 Set Door Relay Time Set door ...

Page 6: ...mal mode factory default Press 35 0 Lock out mode Press 35 1 Note If an invalid card or wrong PIN is input 10 times in 10 minutes user will be locked out for 10 minutes Alarm mode Press 35 2 Note If an invalid card or wrong PIN is input 10 times in 10 minutes external alarm and built in buzzer will sound 8 12 User Optional Setting Setting keypad tone OFF or ON Press 41 0 OFF Press 41 1 ON Default ...

Page 7: ... order User can modify the working mode when the device reset to factory default the setting is still valid 11 1 Wiegand Reader Mode In this mode the access control works as a reader connected with the common access controller It has the following function Modify master pin Set facility code Set the keypad transmission format Set optional setting Anti Tamper alarm When LED level is low indicator l...

Page 8: ...ngle door In this mode this unit install outside is for entering door external reader inside for exiting door the users can only enter door when read valid card on the machine and exit from the inside external reader If without the entering record Note this is only for card users of Zone 1 PIN users of Zone 1 an all users of Zone 1 are invalid GND 12V D1 D0 RF SIB External Reader 12V Power on the ...

Page 9: ...or diagram Mode Anti passback for single door diagram DC12V 3A Special power 1 NC COM NO PUSH GND 12V 12V NO1 COM1 NC1 Blue Purple Orange Relay for zone 1 Power on the lock keep unlocking Power off the lock keep unlocking special power with lock 1 diagram PUSH GND Connect with special power 1 Bell D0 D1 AC1 12V OPEN1 BZ D_IN1 LED GND ALARM1 NO1 COM1 NC1 BELL_A BELL_B Pink Pink Black Red White Gree...

Page 10: ...ON INSTRUCTIONS Alarm Mode Wiegand reader diagram Bell Access Controller D0 D1 GND BZ LED 12V Means connect together D0 D1 AC1 12V OPEN1 BZ D_IN1 LED GND ALARM1 NO1 COM1 NC1 BELL_A BELL_B Pink Pink Black Red White Green Brown Yellow Blue Gray Orange Purple ...

Page 11: ...uld be modified as other PIN 2 Set open mode as entry by card or PIN 3 Alarms at normal condition During installation light leak under bottom During installation device should be close to wall 4 5 Keypad light is not bright Mode of keypad light setting is wrong 1 Set keypad light as shine or auto 2 Under auto mode light shine after press keypad delay 30 seconds 6 Can t enter master mode Forget mas...

Reviews: