background image

 Installation Instructions 

 

 

 

 

 

 

when  any  incorrect  code  has  been  entered,  for  the 
duration that the red LED is illuminated. 
0 = disabled 
1 = enabled 
To disable the audio tone on incorrect code entry: 
First,  enter  program  mode.  Then  enter  [*6],  then  3#, 
then 0 to disable, or 1 to enable, then *. 
 
For  example, 

[*6]  3  #  0  * 

will  disable  the  audio  tone 

on incorrect code entry. 

 
5# Request to Exit Audio Enable/ 
Disable 
 

Default: 0 (Disabled) 
Enable  or  disable  audio  annunciation  for  Relay  #1 
when  a  Request  to  Exit  signal  is  input.  When 
enabled,  if  Relay  1  is  triggered  by  REX  input,  a 
looped  tone  (do-ray)  will  be  annunciated  for  the 
duration  that  Relay  #1  is  energized.  In  the  case  of 
Toggled  mode,  the  annunciation  will  last  for  8 
seconds  (hard-coded).  In  the  case  of  entering  into 
Unlocked  Mode  (REX  input  held  for  more  than  15 
seconds),  4  beeps  will  sound  after  the  looped  two-
tone  annunciation.  A  single  (“Ray-Do”)  tone  will 
sound when exiting Unlock Mode. 
0 = disabled 
1 = enabled 
 
To enable/disable REX Audio Annunciation: 
First,  enter  program  mode.  Then  enter  [*6],  then  5#, 
then 0 to disable, or 1 to enable, then *. 
For  example, 

[*6]  5  #  1  * 

will  enable  the  audio 

annunciation for REX input. 

 
6# Secure LED Annunciator 
Enable/Disable 

Enable  or  disable  the  Red  LED  annunciating  the 
secured status of the locked device.  When enabled, 
the  red  LED  will  light  when  the  keypad  is  secured.  
Once a valid code is entered into the keypad, the red 
LED will turn off and the green LED will illuminate to 
indicate  the  locked  device  is  unlocked.    The  green 
LED  will  remain  lit  for  the  duration  set  by  the  Relay

 

1/Relay2  on-time  duration  setting  or  until  the  locked 
device closes (requires a magnetic door contact).     
0 = disabled (default) 
1 = enabled 
 
To use this feature: 
First  enter  program  mode.    Then  enter  [*6],  6#,  0  to 
disable or 1 to enable, then *. 
For  example, 

[*6]  6  #  1  * 

will  enable  the  red  LED  to 

annunciate the status of the locked device. 
 

 
 

FACTORY DEFAULT SETTINGS 
 

If the settings have not been changed after shipment, 
or if they have been reset, they are as follows: 

Master User # 1 - Code is 1234. 

Main Relay = 8 sec 

Secondary Relay = programmable. 

Yellow LED enabled. 

 
 

Reset Jumper 
 

To reset the Master User Code to factory default: 
There is a three pin header located on the back of the 
keypad. Move the jumper from pins 

2 & 3 

to pins 

1 & 2 

for  at  least  three  seconds,  then  back  to  pins  2  &  3 
again.  
 
During  the  reset,  the  LED’s  will  blink  four  times, and 
an  audio  tone  will  sound.  This  will  reset  the  Master 
code ONLY back to factory default (1234). While the 
default jumper is located on pins 

1 & 2

, the keypad is 

in the “LOCKED” state (no user input is accepted), so 
be sure to move the jumper back to pins 

2 & 3

 
 

[*9] Erase Keypad Memory/Reset ALL to 
Factory 
 

Force factory default settings (use with caution) 
This is used when most or all of the programming has 
to be changed, as when a keypad has been moved to 
a new location. To reset to factory defaults. 
First,  enter  program  mode.  Then  enter  [*9],  then  re-
enter the master keycode, then *. 
 
For  example, 

[*9]  1  2  3  4  * 

will  immediately  and 

permanently  clear  the  entire  memory  (assuming  the 
master  keycode  has  not  been  changed  from  the 
factory default. Once this function has been executed, 
there is NO WAY to restore the previous 

state. 

 
Section 4 _________________ 

 

Technical Data 

 

Models  

 

CM-120i / CM-120W 

 

Illumination  

 

     No   /   Yes 

Size  

 

 

¾

” x 4 

½

” x 

¾

” 

69.85mm x 114.30mm x 
19.05mm 

Mounting  

 

2 x #6-32 machine screws 

Temperature    

-40° - +185°F (-40° - +85°C) 

Operating voltage  

12 / 24 Volts, AC / DC 

Summary of Contents for CM-120wV2

Page 1: ...to Program Keypad Using This Manual Brackets and spaces are not part of the codes They are used here to clarify the operations and group like functions Square brackets are used to indicate that the k...

Page 2: ...details Using with TX 99 Transmitter Another unique feature of our CM 120 keypad is the ability to plug in our TX 99 transmitter to send the signal wirelessly to our RX 91 or RX 92 receiver the keypa...

Page 3: ...enable then For example 1 4 0 will disable the anti tailgating feature 5 Backlight Control Enable Disable applies to CM 120W only Default 0 disabled Enable or disable backlight control on keypress Whe...

Page 4: ...relay on and enter a valid code to toggle the relay back off This is a global setting It is also possible to set for individual users See command 0 further along in this section To program relay 1 op...

Page 5: ...invalid codes on the buzzer only 2 Stuck key alarm Default 0 Disabled Enable or disable the Stuck key alarm 0 disabled 1 enable The Stuck key alarm will activate the buzzer after 15 seconds factory se...

Page 6: ...igit code 0 255 then For example 5 1 66 will configure the keypad to output a 26 bit wiegand protocol with a facility code of 66 6 Annunciation Control Functions 0 Yellow LED Enable Default 1 Enabled...

Page 7: ...closes requires a magnetic door contact 0 disabled default 1 enabled To use this feature First enter program mode Then enter 6 6 0 to disable or 1 to enable then For example 6 6 1 will enable the red...

Page 8: ...make an input error and have not yet entered just wait 5 seconds and the command memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors featur...

Page 9: ...Installation Instructions 9...

Page 10: ...Installation Instructions 10...

Page 11: ...Installation Instructions 11...

Page 12: ...Installation Instructions 12...

Reviews: