CAMDEN CM-120i Installation Instructions Manual Download Page 10

 Installation Instructions 

 

 

 

 

 

10 

 

 

 
 
 
 
 
 

 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 

Summary of Contents for CM-120i

Page 1: ...w to Program Keypad Using This Manual Brackets and spaces are not part of the codes They are used here to clarify the operations and group like functions Square brackets are used to indicate that the keys inside the brackets are to be pressed at the same time Requiring two keys to be pressed simultaneously reduces the chance that someone will accidentally get into programming mode When entering a ...

Page 2: ...e details Using with TX 99 Transmitter Another unique feature of our CM 120 keypad is the ability to plug in our TX 99 transmitter to send the signal wirelessly to our RX 91 or RX 92 receiver the keypad still requires 12 or 24V AC DC power to operate however The RF transmit function even works in Split Output Mode See wiring diagram 3 Page 11 for the RF mounting location SET UP INSTRUCTIONS Note 1...

Page 3: ... enable then For example 1 4 0 will disable the anti tailgating feature 5 Backlight Control Enable Disable applies to CM 120W only Default 0 disabled Enable or disable backlight control on keypress When enabled the backlight will be OFF until the first keypress It will remain on for 5 seconds after the last keypress When disabled the backlight will remain ON continuously 0 disabled 1 enabled To en...

Page 4: ...e relay on and enter a valid code to toggle the relay back off This is a global setting It is also possible to set for individual users See command 0 further along in this section To program relay 1 operate time First enter program mode Then enter 3 then 0 then the active time in seconds 0 toggled then For example 3 0 30 will set relay 1 operate time to 30 seconds 2 Door Prop open Alarm Delay Defa...

Page 5: ... invalid codes on the buzzer only 2 Stuck key alarm Default 0 Disabled Enable or disable the Stuck key alarm 0 disabled 1 enable The Stuck key alarm will activate the buzzer after 15 seconds factory set delay of the key being held continuously and reset as soon as the key is released or after 10 seconds whichever occurs first To enable the stuck key alarm First enter program mode Then enter 4 then...

Page 6: ...digit code 0 255 then For example 5 1 66 will configure the keypad to output a 26 bit wiegand protocol with a facility code of 66 6 Annunciation Control Functions 0 Yellow LED Enable Default 1 Enabled Enable or disable the yellow LED When enabled the yellow LED illuminates when any key is pressed 0 disabled 1 enabled To disable the yellow LED First enter program mode Then enter 6 then 0 then 0 to ...

Page 7: ... closes requires a magnetic door contact 0 disabled default 1 enabled To use this feature First enter program mode Then enter 6 6 0 to disable or 1 to enable then For example 6 6 1 will enable the red LED to annunciate the status of the locked device FACTORY DEFAULT SETTINGS If the settings have not been changed after shipment or if they have been reset they are as follows o Master User 1 Code is ...

Page 8: ...u make an input error and have not yet entered just wait 5 seconds and the command memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors feature is disabled by default This will prevent the keypad from hanging up if anyone plays with the keypad in certain applications o Do not make the mistake of thinking you have to clear the red light if ...