CAMDEN 634W Quick Start Manual Download Page 2

 

NOTES: 

 

1. 

Wiegand keypads are programmed with default Site Code “000”.

 

To change this Site Code perform the following functions: 
 
Disconnect the power for a minimum of 10 Sec.  
Connect Power. 
Perform the following functions within 3 Sec. Of applying power. 
 

Enter * on Keypad.                                                    Keypad enters program mode (Red Led    

flashing) 

Enter new Site Code followed by the # sign.  

The new Site Code is assigned 

 
2. 

Blue Wire

  PRESSING any key on the keypad will generate a 30 second 0.25 amp intermittent 

duty grounding output. 

 

3. 

Orange Wire

  When the Hold Line, Orange wire, is pulled "low", any codes entered on the 

keypad are stored in the buffer. When the Hold Line is released to a logic "high" - the buffered 
code data is sent. 

 

3. 

Grey Wire

  When the photodiode senses ambient light, the grey wire is pulled "LOW" 

 

This Photodiode is mounted on the back of the Keypad. When installing this unit be careful 
not to damage the Photodiode.  

 
 

5.  An error code is generated by any of the following: a) Pressing the # key with no preceding 

digits; b) Pressing any number of only zero's prior to pressing the # key, or; c) Pressing 65,535 or 
any number above 65,535. An Error Code will send all binary l's to your pane1. 
Do Not Program your panel to accept code number 65,535. 

 

Questions? 

Call Camden tech support @ 1-877-226-3369 

Filename: CM-634W Instructions.doc 
Version: 10/20/2005 3:31 PM 

Reviews: