4 OPER
ATION
USER MANUAL
VORTEX 6, 4, 2.6 and 200V
P.16
USER MANUAL
VORTEX 6, 4, 2.6 and 200V
P.17
4.1.2 Gain Selector
This switch on the rear of the
VORTEX
allows the maximum amplification
attainable to be set directly in the input stage.
The
VORTEX
amplifier has a 26 dB and 32 dB
voltage gain setting along with a 1,4 V sensitivity
setting.
4.1.3 Gain and Input Sensitivity
The table shows input sensitivity per channel for a given gain and load. It also
shows the gain for the 1,4 V input sensitivty.
Model
26 dB
32 dB
1,4 V
VORTEX 200V
4
Ω
@ 3200 W
8
Ω
@ 1900 W
16
Ω
@ 1000 W
5,67
6,18
6,34
2,84
3,10
3,18
39,0 dB
VORTEX 6
2
Ω
@ 3000 W
4
Ω
@ 2100 W
8
Ω
@ 1200 W
3,88
4,59
4,91
1,95
2,30
2,46
37,5 dB
VORTEX 4
2
Ω
@ 2000 W
4
Ω
@ 1500 W
8
Ω
@ 920 W
3,17
3,88
4,30
1,59
1,95
2,15
35,3 dB
VORTEX 2.6
2
Ω
@ 1300 W
4
Ω
@ 750 W
8
Ω
@ 450 W
2,56
2,75
3,01
1,28
1,38
1,51
32,0 dB
4.1.3 Limiter Switch
This switch is located at the rear of
VORTEX
. It allows you to set the mode of
the limiter. There are three modes
(See 4.3.1 Clip Limiter and 4.3.4 Speaker Protect
Limiter)
:
Right position:
Clip Limiter: On
Speaker Protect: On
Middle position:
Clip Limiter: Off
Speaker Protect: On
Left position:
Clip Limiter: Off
Speaker Protect: Off
4.2 Indicators
4.2.1 On LEDs (multifunctional)
Under normal operation, after the amp has started, the green On LEDs are
permanently lit. A variety of different sequences of flashing LEDs are used to
indicate other operating states and errors in the relevant channels of the power
amp.
(See 6.1 Flashing sequences for On LEDs)