INSTALLATION INSTRUCTIONS

Many codes and regulations do not allow the use 
or storage of portable LP Gas cylinders larger 
than 2 lb. water capacity in structures. Check with 
your local regulatory authority before using your 
Olympian

 heater indoors with larger cylinders.

Fuel

The heater is designed for use with HD-5 propane gas 
only. Do not attempt to convert it for use with natural gas, 
other LP Gases, or other fuels gaseous or liquid. Use of any 
propane gas other than HD-5 may cause damage to the 
catalytic heating element. 

THIS HEATER 

CANNOT

 BE 

CONVERTED TO ANY OTHER FUEL SOURCE.

Locations

Due to high temperatures, the appliance should be located 
out of traffic and away from furniture and draperies. Children 
and adults should be alerted to the hazard of high surface 
temperature and should be kept away to avoid burns or 
clothing ignition. Young children should be carefully supervised 
when they are in the same room with the appliance.

The ideal location for the operation of your heater is as 
low as possible to radiate heat in the frontal direction. The 
heating element will throw a beam of infrared heat. Ideally, 
this beam of heat should be pointing at the area, objects or 
persons you wish to heat. The infrared heat beam will heat 
up the objects and then become convection heat, eventually 
heating the surrounding air.

If you have a question regarding the location for installation 
of your heater, call Technical Support at (336) 668-7661.

Do not place clothing or other flammable material on or 
near appliance. INSTALLATION AND REPAIR SHOULD BE 
DONE BY A CERTIFIED LP GAS SERVICE TECHNICIAN. 
The appliance should be inspected before use and at least 
annually by a professional service person. More frequent 
cleaning may be required due to excessive lint from 
carpeting, bedding material, etc.

The heater may be installed in a variety of fixed locations.  
It also may be used as a portable heater by using optional  
leg stands.

Consistent with other requirements, keep the gas supply line 
from the tank to the heater as short as possible.

The installation including that of the gas supply 
system must conform with all applicable state and 
local codes and with the National Fuel Gas Code 
ANSI Z223.1.

Installation should be performed only by qualified LP Gas 
service personnel familiar with non-vented gas space 
heaters. See section titled

 Gas Supply.

Clearances from combustible materials must be a minimum of:

•  4" from each side
•  4" from the floor (rug, tile, etc.)
•  18" from the top
•  30" from the front
•  0" from the rear

Heater Connection

The 3/8" male and female SAE flare connectors must be 
checked and cleaned before assembly and then wrenched 
securely for a gas-tight connection. Apply Camco Gas Leak 
Detector to joints and watch for bubbles to check for gas leaks.  

DO NOT USE ANY EXPOSED FLAME TO CHECK FOR LEAKS. 
DO NOT OVERTIGHTEN.

Mounting Heater on Wall

The Olympian™ Wave 6 and Wave 8 can be hung on the wall in a 
vertical or horizontal position. 

The Wave 3 can only be mounted 

in the vertical position.

Controls must be at the bottom when the heater is 
mounted vertically.

Controls must be at the right with the control knob at 
the upper right corner when the heater is mounted 
horizontally.

 This is for easy use and proper operation of the 

heater.

Follow these easy mounting steps:

1.  Material on which heater is to be mounted must be firm and 

structurally strong.

2.  Screws and plastic anchors for installation are found in the 

accessories bag furnished with the heater.

3.  Cut out the four corners on the Mounting Template furnished 

with the heater. Use the Template to locate vertical or 
horizontal mounting hole positions.

4.  Drill 3/8" diameter hole in wall for plastic anchors, according 

to horizontal or vertical surface installation holes on mounting 
template.

5.  Push plastic anchors into the holes.
6.  Thread screws in the plastic anchors.

Summary of Contents for OLYMPIAN Wave3

Page 1: ... in a place that will block the heat rays Your Olympian heater has undergone rigorous safety performance and quality assurance testing before leaving the factory It is designed to deliver years of trouble free service The INSTALLER must leave this set of instructions with the owner after installation is completed IMPORTANT Installers must have the owner fill out and mail the warranty card supplied...

Page 2: ...your gas supplier LP Gas Warning Odor If a gas leak happens you should be able to smell the gas because of the odorant put in the LP Gas That s your signal to go into immediate action Do not operate electric switches light matches or use your phone Don t do anything that could ignite the gas Get everyone out of the building vehicle trailer or area IMMEDIATELY Close all gas tank or cylinder supply ...

Page 3: ... it goes completely empty or by having it refilled before it is completely empty SAFETY INFORMATION FOR USE OF LP GAS cont SAFETY INFORMATION FOR USE OF LP GAS cont Gas Supply The installation must conform to local codes In the absence of local codes the installation must conform with American National Standard National Fuel Gas Code known as NFPA 54 and ANSI Z223 1 2002 or the latest edition Avai...

Page 4: ...e installed in a variety of fixed locations It also may be used as a portable heater by using optional leg stands Consistent with other requirements keep the gas supply line from the tank to the heater as short as possible The installation including that of the gas supply system must conform with all applicable state and local codes and with the National Fuel Gas Code ANSI Z223 1 Installation shou...

Page 5: ...e back of the case is 1 3 4 This is the maximum recess depth 5 Using the ring as a template carefully drill 7 64 diameter screw holes through the heater case at the side and top Be careful of internal gas lines 6 Fasten the recess mounting ring to the heater case using the 6 x 3 8 lg panhead tapping screws included in the recess mounting kit 7 Fasten the heater and mounting ring assembly to the wa...

Page 6: ...ul burns Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any p...

Page 7: ...eep the gas valve open 7 When ignition occurs you will see small blue flames dancing over the catalyst pad face while it heats up This flaming is normal during start up of the heater as this begins the catalytic combustion process Flaming may occur several times during the heating up period 8 Release the control knob push know in slightly and immediately turn it to HIGH heat setting Done properly ...

Page 8: ...hould be turned off as close to the gas source as possible In the case of portable use the gas should be turned off at the propane LP supply cylinder In the case of wall mounted heaters there should be a manual gas valve installed near the heater Service With good care and normal operating conditions your Olympian Catalytic Heater should provide many years of warmth and comfort The following servi...

Page 9: ...pane Use of other LP Gases such as those too high in sulfur propylene or other hydrocarbons may injure the catalyst pad Gas or sludge from the inside of old or dirty cylinders may block out the catalyst and prevent it from working Dirty or improper gas may plug the orifice and restrict the gas supply to the catalyst pad Symptoms of this are Heater won t light or will only light partially Gas odor ...

Page 10: ...ter model and serial number The heater is designed as a non vented gas fired space heater Such heaters have many uses in residential agricultural industrial trade service and recreational applications Its use is intended for purposes described and limited by any applicable standards Camco cannot anticipate all of the many applications for which catalytic heaters may be used This heater should not ...

Page 11: ...s liability for indirect or consequential damage to property Warranty repairs must be made by Camco Mfg Inc Leg Stands To make Olympian Wave heaters portable Leg stands fit all heaters models Wave 3 Wave 6 and Wave 8 Part No 57701 Custom Fitted Dust Covers Model Part No For wall mount heaters Wave 3 57706 Wave 6 57713 Wave 8 57715 For portable heaters with leg stands Wave 3 57722 Wave 6 57723 Wave...

Page 12: ...s Chrome Recess Kit for Wave 6 57692 22 95 Chrome Recess Kit for Wave 8 57695 27 55 subtotal 6 75 Sales Tax NC Residents only Shipping Handling TOTAL Payment Method Check MasterCard _ ___________________________________ VISA __________________________________________ Card Expiration Date ______________________________ Signature _________________________________________ Ship to Name _______________...

Reviews: