Camco OLYMPIAN Wave3 Installation Information Download Page 1

1

Your Olympian

 heater is designed and 

built to provide years of comfortable, 
radiant heat and economical LP Gas 
consumption. In order to minimize 
installation problems and maximize 
your heating comfort, read all of these 
instructions carefully and completely.

Olympian heaters produce mostly radiant 
heat as a result of a flameless catalytic 
combustion process. Its efficiency 
is high because combustion takes 
place at relatively low temperatures.

The wavelength of the radiant heat 
produced by Olympian heaters is 
particularly effective for creating 
a feeling of warm comfort similar 
to solar radiation. The sun is an 
excellent example of radiant heat 
transfer, because it transmits energy 
through space, releasing heat when 
its rays strike objects and people.

Like the sun, Olympian heaters radiate 
heat directly to people, floors, walls 
and other objects without heating the 
air first, so warmth is felt immediately. 
Radiant heat is absorbed by objects 
and then emitted into the air to heat 
the surrounding area. Therefore, your 
Olympian heater should be oriented to 
direct its heat rays toward the space 
to be heated, much like a floodlight is 
positioned to illuminate a desired area. 
Avoid placing furniture or objects in a 
place that will block the heat rays.

Your Olympian heater has undergone 
rigorous safety, performance and 
quality assurance testing before 
leaving the factory. It is designed to 
deliver years of trouble-free service. 

The INSTALLER must leave this set 
of instructions with the owner after 
installation is completed. (IMPORTANT: 
Installers must have the owner fill out 
and mail the warranty card supplied 
with each heater.) The OWNER should 
read this entire manual to be assured 
of a satisfactory installation and to 
fully understand operating procedures. 

Keep these instructions in a safe, 
convenient place for future reference.

Installation and Operating Instructions

NOTICE

WARNING:

 CAREFULLY READ THE FOLLOWING INSTALLATION INFORMATION.

EFFECTIVE DATE: JANUARY 2009

Models:

This is a heating appliance. Any safety screen or guard removed for servicing must be replaced prior to operating the heater.

Any changes or alterations to this heater or its controls (or attempts to clean 
the catalytic pad) can result in damage, defective operation, fire, explosion, 
asphyxiation and/or burns.

If product components are missing or damaged do not return to dealer.

Contact the manufacturer at (336) 668-7661

Catalytic Safety Heater

CALIFORNIA PROPOSITION 65 WARNING:
Combustion by-products produced when using 
this product contain chemicals known to the 
State of California to cause cancer and/or birth 
defects or other reproductive harm.

Summary of Contents for OLYMPIAN Wave3

Page 1: ... in a place that will block the heat rays Your Olympian heater has undergone rigorous safety performance and quality assurance testing before leaving the factory It is designed to deliver years of trouble free service The INSTALLER must leave this set of instructions with the owner after installation is completed IMPORTANT Installers must have the owner fill out and mail the warranty card supplied...

Page 2: ...your gas supplier LP Gas Warning Odor If a gas leak happens you should be able to smell the gas because of the odorant put in the LP Gas That s your signal to go into immediate action Do not operate electric switches light matches or use your phone Don t do anything that could ignite the gas Get everyone out of the building vehicle trailer or area IMMEDIATELY Close all gas tank or cylinder supply ...

Page 3: ... it goes completely empty or by having it refilled before it is completely empty SAFETY INFORMATION FOR USE OF LP GAS cont SAFETY INFORMATION FOR USE OF LP GAS cont Gas Supply The installation must conform to local codes In the absence of local codes the installation must conform with American National Standard National Fuel Gas Code known as NFPA 54 and ANSI Z223 1 2002 or the latest edition Avai...

Page 4: ...e installed in a variety of fixed locations It also may be used as a portable heater by using optional leg stands Consistent with other requirements keep the gas supply line from the tank to the heater as short as possible The installation including that of the gas supply system must conform with all applicable state and local codes and with the National Fuel Gas Code ANSI Z223 1 Installation shou...

Page 5: ...e back of the case is 1 3 4 This is the maximum recess depth 5 Using the ring as a template carefully drill 7 64 diameter screw holes through the heater case at the side and top Be careful of internal gas lines 6 Fasten the recess mounting ring to the heater case using the 6 x 3 8 lg panhead tapping screws included in the recess mounting kit 7 Fasten the heater and mounting ring assembly to the wa...

Page 6: ...ul burns Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any p...

Page 7: ...eep the gas valve open 7 When ignition occurs you will see small blue flames dancing over the catalyst pad face while it heats up This flaming is normal during start up of the heater as this begins the catalytic combustion process Flaming may occur several times during the heating up period 8 Release the control knob push know in slightly and immediately turn it to HIGH heat setting Done properly ...

Page 8: ...hould be turned off as close to the gas source as possible In the case of portable use the gas should be turned off at the propane LP supply cylinder In the case of wall mounted heaters there should be a manual gas valve installed near the heater Service With good care and normal operating conditions your Olympian Catalytic Heater should provide many years of warmth and comfort The following servi...

Page 9: ...pane Use of other LP Gases such as those too high in sulfur propylene or other hydrocarbons may injure the catalyst pad Gas or sludge from the inside of old or dirty cylinders may block out the catalyst and prevent it from working Dirty or improper gas may plug the orifice and restrict the gas supply to the catalyst pad Symptoms of this are Heater won t light or will only light partially Gas odor ...

Page 10: ...ter model and serial number The heater is designed as a non vented gas fired space heater Such heaters have many uses in residential agricultural industrial trade service and recreational applications Its use is intended for purposes described and limited by any applicable standards Camco cannot anticipate all of the many applications for which catalytic heaters may be used This heater should not ...

Page 11: ...s liability for indirect or consequential damage to property Warranty repairs must be made by Camco Mfg Inc Leg Stands To make Olympian Wave heaters portable Leg stands fit all heaters models Wave 3 Wave 6 and Wave 8 Part No 57701 Custom Fitted Dust Covers Model Part No For wall mount heaters Wave 3 57706 Wave 6 57713 Wave 8 57715 For portable heaters with leg stands Wave 3 57722 Wave 6 57723 Wave...

Page 12: ...s Chrome Recess Kit for Wave 6 57692 22 95 Chrome Recess Kit for Wave 8 57695 27 55 subtotal 6 75 Sales Tax NC Residents only Shipping Handling TOTAL Payment Method Check MasterCard _ ___________________________________ VISA __________________________________________ Card Expiration Date ______________________________ Signature _________________________________________ Ship to Name _______________...