4.3. Connecting to the mains
Connect the Power Supply Unit (PSU) to the hub using the 4-pin DIN plug. Connect the power
cable to the PSU. Making sure you adhere to local safety regulations, connect the power cable
to the 100 – 250 VAC mains power outlet and switch the hub on using the small power switch
located adjacent to the power input connector on the hub. When the device is switched on, a
red LED will be illuminated. The hub is now ready to charge attached devices.
Periodic inspection should be made to power supply cables and any USB cables for any signs of
damage. If any damage is found then replace damaged cord before further use.
Please note that USB specifications require a minimum 100 mA charge current to be delivered
during data transfer. As indicated in above, if the attached device has a BC1.2 compliant CDP
port, the device can draw up to 2.4A while transferring data.
4.4. Registration
You may register your product at
www.cambrionix.com/product-registration
4.5. Help and Support
FAQs and help can be found on the Help page here
l
www.cambrionix.com/help_pages/help
.
You can raise a support ticket for more in depth support here
l
https://cambrionix.atlassian.net/servicedesk/customer/portals
You can also download any of our manuals and keep up to date at the link here
l
www.cambrionix.com/product-user-manuals
When contacting support it will be helpful to supply us with the product information for the
hub in question. This can be found on the Device Information Plate which is either on the
underside or back of the unit. Including serial and PO numbers can help identify the product in