www.CambridgeElevating.com
August 2017
5
Description of Elevator Equipment
General
Rated load: Up to 1,500 lbs. where permitted
by local codes
Nominal speed: 40 feet per minute
Elmira
minimum pit depth: 8”
Elmira
minimum overhead clearance: 96”
Heritage/Cambrian
minimum pit depth: 12”
Heritage/Cambrian
minimum overhead: 108”
Maximum travel: 50 feet
Maximum number of stops: 6
Mechanical Equipment
220 VAC, 60 Hz, 30 Amp single phase power
Dual 8 lb. modular T-rail system
Two 3/8” diameter, 17 x 9 wire ropes
Sling assembly
Forged rope sockets
2:1 roped hydraulic single stage cylinder
Submersed electric motor with 2-speed
adjustable valve system
Cab and Appointments
Car size: Up to 20 sq. ft. standard
Cab height:
84" standard, 96" & custom optional
Recessed
LED
cab lights – 2 or 4 lights depending
on cab size
Interior cab walls and ceiling finish, choice of:
Melamine
:
cherry, oak,
maple,
walnut, white
, black
Veneer (unfinished) –birch, cherry, maple, oak,
walnut
(MDF) Medium density fibreboard – paint grade
Rough plywood cab floor with ¾” recess
Gates and Doors
Elmira
Swing door for each landing
Horizontally collapsible accordion style car gate(s)
Heritage
Swing door for each landing
Automatic sliding cab door panels
(
beige
or s/s)
Cambrian
Automatic sliding cab door panels
(beige or s/s)
Automatic sliding landing door panels
(beige or s/s)
Controls
Microprocessor controller with relays for basic
operation
Fully automatic operation
Automatic timed cab lighting
Stainless steel car operating panel (COP),
telephone box and hall call stations
Dual illuminated hall call station push buttons
and position indicating push buttons on COP
Emergency stop switch on COP
LED/dot matrix Digital Position Indicator (DPI)
in car
Safety Devices
Stainless steel handrail inside cab
220 VAC lockable disconnect for
p
ower unit
Final limit switch
Slack rope safety switch
Pit stop switch
Car top stop switch
Line rupture valve
Low pressure switch
Automatic leveling (anti-creep)
Emergency battery lowering
Electro-mechanical door interlocks
Manual lowering device
Telephone in cab
Options
Custom cab sizes/heights. Oversized cabs
where permitted (variance may be required)
Unfinished oak, maple or cherry solid
hardwood / face frame hardwood cab walls and
ceiling
Stainless steel patterned cab walls and ceiling
Custom finish elevator fixtures (COP, telephone
box and hall call stations) in choice of plating
finishes: Brushed brass, oil rubbed bronze,
polished stainless, brushed nickel, consult
factory for additional choices.
Two piece hydraulic jack
Additional handrails in cab
Handrail COP (all models)
LED/dot matrix Digital Position Indicator (DPI)
hall call stations on landings
Veneer and decorative metal wrapped sliding
door panels (Heritage/Cambrian)
Summary of Contents for Elmira
Page 8: ......