RESIDENTIAL ELEVATOR 

SERVICE GUIDE  

TECHNICAL SUPPORT: 

Call or Text: 866-209-3421 

Technical information web site: 

cambridgeelevating.com/technicians/

 

Email: 

[email protected] 

 

Refer to OLS operator manual, BES3 installation manual, 

BES3 service manual, electrical drawings, hoist-way 

layout, and CE connection drawings for details. 

 

1XX  Communications module codes   

121 - Remote monitoring reset 

123 - Started communicating 

123_3_# - System startup 

1234567 - Service mode 

124 - Module software update 

125 - Module self-reset timer 

126 - Module self-reset 

127 - Module remote reset 

131 - Drop in communications 

132 - Remote report request 

134 - Multiple self-reset 

135 - Module self-reset, timer 

141 - System voltage < 24Vdc 

142 - Releveled >=5 times a day 

143 - Calls were over 30 for day 

145 - Communications failure 

147 - Landing door left open 

150 - MCP 5 day turnover 

151 - MCP 6 month 

152 - MCP 12 month 

153 - MCP 60 month 

171,172 - R&D test 

 

 

 

3XX  System will not take a call due to… 

312 - Light curtain is blocked 

313 - No 120Vac or 220Vac 

314 - Main controller safety 

315 - Car-top safety activated 

316 - COP e-stop is open 

317 - System is in service mode 

321 - System voltage very low 

323 - Battery capacity very low 

325 - Battery faulty 

326 - DC power fault 

327 - DC power low 

341 - Run timer fault 

342 - Car-top relay monitor 

343 - Gate safety monitor 

345 - Contactor monitor 

346 - Light curtain is not working 

347 - Landing door contact failed 

351 - Floor relay monitor 

352 - Landing door cancelled call 

353 - Cab gate canceled call 

354 - Positioning system error 

356 - Light curtain blocked 

357 - Floor relay monitor 

361 - Cab Gate left open for more than 10 seconds 

**362 - Elevator training 

364 - System failed to find a floor 

**365 - Landing door safety fault 

371 - MCU chip failed, replace 

 

 

 

4XX  MCU fault codes 

412 - MCU data is invalid 
423 - MCU external oscillator failure 
 
 

 

5XX  Startup cannot proceed due to… 

512 - A landing door is open 

513 - A cab gate is open 

514 - Main controller safety 

515 - Car-top safety activated  

516 - Light curtain blocked 

517 - No 120 or 220Vac 

521 - Low DC voltage 

523 - DC Power system failure 

524 - Battery recharging  

525 - Very low battery capacity 

531 - MCU chip internal failure 

532 – Car-top relay fault monitor 

5353 - Software version error 

543 - Internal fault monitor 

**545 - Contactor monitor 

**562 - Elevator training 

**565 - Landing door safety fault 

 

 

 

7XX  Startup was suspended due to… 

7 (steady) - MCU Program not running, check MCU chip 

721 - Cab did not move 

723 - Low up speed 

724 - Low / no down speed 

725 - Low down leveling speed 

727 - No up movement 

731 - Positioning system fault 

732 - Contactor overload tripped 

734 - Door zone fault 

735 - Positioning sensor spacing 

741 - Top cam too high or missing 

751 - Floor relay fault or F4 fuse      

** A hard reset is required, see service manual section K. 

Customers should never be instructed on how to do a hard 

reset. 

 

 

 

Setting Floor Levels  

Note: System must be in automatic and able to take calls. 

1. Travel to a floor using a car call button. 

2. Open COP to access leveling controls. 

3. Press and hold 2 enable buttons. 

4. Use up and down buttons to move the car up and down 

until it is level with the floor. Remember to account for 

flooring if it is not installed yet. 

5. As soon as you let go of the enable buttons, the new 

position will be stored in memory. 

6. If the car will move up and down but not far enough, you 

will need to move the coded strip for that floor: 

a. If you move the car up but the car is still too low, move the 

strip up one inch more than the distance you are short. 

Return to step 1). 

b. If you move the car down but the car is still too high, move 

the strip down a little more than the distance you are short. 

Return to step 1). 

7. Once all floors have been leveled, travel back to each floor 

to confirm level is correct. 

Note: Unlike our previous model, you do not have to be in 

service mode. 

 

 

Setting the Number of Stops  

Note: System must be in automatic and able to take calls. 

1. Restart the system, cab should travel to the top floor.  

2. Gain access to the car and open the COP  

3. Press and hold 2 enable buttons. 

4. While still holding the 2 enable buttons, reach around 

immediately and hold the top floor button. 

5. All the COP call buttons will flash for 15 seconds or so.  

6. The DPI should change to the top floor # or symbol. 

7. Let go of the enable and call buttons. 

Note: Unlike our previous model, you do not have to be in 

service mode. 

 
 