YCV 100, VYC 100N, VYC 100P • Installation and Operation
YCV 100, VYC 100N, VYC 100P • Installation and Operation
Installation and Operation, cont’d
2-6
Projector mounting
Projector mount the YCV 100, VYC 100N, or VYC 100P using the
optional mounting kit (part #70-217-01) as follows:
1
.
Remove rubber feet if they were previously installed on the
bottom of the unit.
2
.
Attach the projector mounting brackets to the unit with the
machine screws provided.
3
.
Secure the unit below the ceiling to a projector mount or
other surface by inserting the mounting bolt through the
bracket’s slotted hole, as shown below.
Digit
a
l Projector
Projector
Mounting
Br
a
cket
Ceiling
Y
C
V
1
0
0
S
-V
ID
E
O
E
N
C
O
D
E
R
P
O
W
E
R
V
ID
E
O
O
U
T
S
-V
ID
E
O
I
N
O
R
Y
C
1
2
V
0
.5
A
M
A
X
Mounting
Bolt
Mounting the YCV 100, VYC 100N, and VYC 100N
on a projector mount
Front Panel Features
1
1
Power LED
— Lights to indicate that the YCV 100/VYC 100N/
VYC 100P is on.
2-7
Rear Panel Features and Cabling
YCV 100
YCV 100
S
-VIDEO
ENCODER
POWER
VIDEO OUT
S
-VIDEO IN
OR
Y
C
12V
0.1A MAX
3
4
1
2
1
Input connectors
— Connect an S-video source to either:
• the two female BNC connectors or
• the 4-pin mini DIN connector.
Do not connect S-video sources to both types of
connectors at the same time.
2
Output connector
— Connect a composite video output device
to this female BNC connector.
3
Power connector
— An external 12 V power supply is included
with the unit. Plug it into this 2-pole captive screw connector.
Wire the connector as shown below.
CAUTION
When connecting the power supply, voltage
polarity is extremely important. Applying power
with incorrect voltage polarity could damage the
power supply and the YCV 100. Identify the power
cord negative lead by the ridges on the side of the
cord or a black heat shrink wrapping around it.
Power S
u
pply
O
u
tp
u
t cord
Captive Screw
Connector
0.2” (5 mm)
12V
Ridges
Smooth
Strip the insulation from the wires to expose 5 mm
(0.2") of the conductors. Do not tin the stripped power
supply leads before installing the captive screw
connector. Tinned wires are not as secure in the captive
screw connectors and could be pulled out.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
To verify the polarity before connection, check the no load
power supply output with a voltmeter.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203