background image

XR-320  Series Installation

2

48 VDC

—if you do not power the AP using PoE, you may power it using a 48 VDC adapter instead, as 

described below in “Supply Power” under the 

The wall AP has the following ports and jacks. For the 

UPLINK-PoE+ and Pass-Through ports, you may use either an RJ-45 or a punch-down connection.

 section. 

Preparation

Run a data uplink cable (Cat5e/Cat6) for the Gigabit uplink port.

Supply power—the XR-320 is powered via IEEE 802.3af or 802.3at Power over Ethernet (PoE) on the same 
cable as the data uplink. Alternatively, you can use a 48 VDC power adapter to power the AP instead of PoE.

The total PoE uplink cable length must be no more than 100 m, including all cable segments. The AP must be connected 
to PoE networks without routing cables to the outside plant. 

Some of the wall AP’s power can be used to supply 802.3af power to a device connected to the LAN4-PoE 
switch port. For this application, you must meet one of the following conditions.

Supply 802.3at PoE power to the UPLINK-PoE+ port. 

Or you can supply your own local 48 VDC power adapter meeting these specifications: 

Pass-through port—this connection is optional.

LAN ports—these four switch ports on the bottom of the XR-320 allow you to provide Ethernet connectivity to 
other devices. These connections are optional.

Wall Installation 

Figure 2

Locking 

tab

XR-320 APs should be mounted on an inside wall.

1.

Remove the blank wall plate from the wall with a screwdriver. 

2.

As shown in 

Figure 2

, feed the Uplink (PoE) and optional Pass-

Through cables through the opening in the supplied mounting bracket 
and secure the bracket to the wall using the two screw holes 
previously occupied by the blank wall plate. Ensure that the “UP” 
label is at the top, and that the tab for the locking screw is on the left facing towards you. 

3.

Connect the cables as follows. Plug the Uplink-PoE+ and optional Pass-Through cables into their respective 
sockets as shown in 

Figure 3

 (A). If the cables are not fitted with RJ-45 jacks, they can be connected to the 

punch down blocks using a dedicated network cable tool according to the sequence of colored wires marked 
on the back of the AP, as shown in 

Figure 3

 (B).

Output Power

 +48VDC

Nominal Load Current

 0.63A

Ripple and Noise

 At 20Mhz, and output parallel with 0.1uF and 10uF 

capacitors to ground, temperature at 25

°

C, at 

nominal input voltage

Connector

 Jack Plug 55*2.5*11.5mm

Polarity

 