Chapter 7: Operation
System summary and status
Page 7-7
Figure 211 System Status page (Slave, HCMP topology)
In the HCMP topology, one PTP 670 Series unit is the Master and up to eight PTP 670 Series
units are configured as Slaves. The roles of the units in this relationship are displayed in the
page title. The master unit will always have the title “
- High Capacity MultiPoint -
Master
”, and the slave will always have “
- High Capacity MultiPoint - Slave
”
appended to the “
Systems Status
” page title.
Procedures:
•
Only on a device configured as in HCMP mode as a Master, set the Wireless Interface
Selector to the Wireless Interface the diagnostic data needs to be displayed for. Note the
Remote MAC Address indicates the MAC address of the unit currently connected, if any, to
the selected wireless interface.
•
Confirm that the NIDU LAN Port Status attribute and the TDM Channel Status are green
and set to Copper Link Up and Up respectively.
Equipment
The Equipment section of the System Status page contains the attributes described in
Table 195 System Status attributes - Equipment
Attribute
Meaning
Link Name
The link name is allocated by the system administrator and is used to
identify the equipment on the network. The link name attribute is limited
to a maximum size of 63 ASCII characters.