Chapter 5: Radio Configuration
Configuring and Viewing Radio PMs and Statistics
phn-3963_008v000
Page 5-14
Table 26
Signal Level Thresholds
Parameter
Definition
RX Level Threshold 1
(dBm)
Specify the threshold for counting exceeded seconds if the RSL is below
this level.
RX Level Threshold 2
(dBm)
Specify a second threshold for counting exceeded seconds if the RSL is
below this level.
TX Level Threshold (dBm)
Specify the threshold for counting exceeded seconds if the TSL is below
this level.
Displaying Modem BER (Aggregate) PMs
To display modem BER (Bit Error Rate) PMs per radio:
1.
Select
Radio > PM & Statistics > Aggregate
. The Aggregate PM report page opens.
Figure 66
Aggregate PM Report Page
2.
In the
Interval Type
field:
o
To display reports in 15-minute intervals, select
15 minutes
.
o
To display reports in daily intervals, select
24 hours
.
describes the Modem BER (Aggregate) PMs.
Note
To display the same parameters for a specific interval in a separate page, select the interval in the
Modem BER PM table and click
View
.
Table 27
Modem BER (Aggregate) PMs