Chapter 2: Getting Started
Configuring Unit Redundancy for the PTP 820G
phn-3965_006v002
Page 2-28
Figure 29
Standby Tab of Unit Redundancy Page
Viewing Link and Protection Status and Activity
You can view link and protection status and activity any time.
To view link and protection status and activity:
Select
Platform > Management > Unit Redundancy
. The Unit Redundancy page opens (
).
The following information is displayed:
•
Protection Operational State
–
Indicates whether unit redundancy is functional. Radio protection is not
functional if the management connection to the mate is down.
•
Protection Activity
–
The activity state of the device: Active or Standby.
•
Protection Link to Mate
–
Indicates whether the two units (the Active and the Standby) are physically
connected.
•
Copy to mate status
–
Indicates the status of the last copy-to-mate operation
•
Protection Admin
–
Indicates whether unit redundancy is enabled or disabled.
•
Lockout
–
Indicates whether lockout is enabled or disabled.
Switchover
The following events trigger switchover for unit redundancy according to their priority, with the highest priority
triggers listed first.
1.
Loss of active unit
2.
Force switch
Summary of Contents for PTP 820 Series
Page 1: ...User Guide ...
Page 49: ...Chapter 1 Introduction Configuration Tips phn 3965_006v002 Page 1 3 ...
Page 162: ...Chapter 3 Configuration Guide System Configurations phn 3965_006v002 Page 3 4 ...
Page 294: ...Chapter 4 Unit Management Upgrading the Software phn 3965_006v002 Page 4 19 5 Select FTP ...
Page 713: ...Chapter 14 Getting Started CLI Configuring the Activation Key CLI phn 3965_006v002 Page 14 18 ...
Page 731: ...Chapter 14 Getting Started CLI Operating in FIPS Mode CLI phn 3965_006v002 Page 14 36 ...