Chapter 4: Legal and regulatory information
Compliance with safety standards
Page 4-25
Table 75 FCC minimum safe distances – PMP 450m 5.1 GHz, 5.2 GHz, 5.4 GHz and 5.8 GHz
Band (GHz) Antenna
PG (W)
S (W/ m
2
)
d (m)
5.1 90°
sector
3.38
10 0.16
5.2 90°
sector
0.85
10 0.08
5.4 90°
sector
0.85
10 0.08
5.8 90°
sector
3.38
10 0.16
Table 76 FCC minimum safe distances, 40 MHz Channel Bandiwdth – PMP/PTP 450i 3.65 GHz, 5.4
GHz and 5.8 GHz
Band
Antenna
P burst
(W)
P
(W)
G
(dBi)
S
(W/ m
2
)
d
(m)
3.65
GHz
90° sector antenna,
integrated
-
0.020
50.1 (17 dBi)
10.0
0.09
5.4
GHz
90° sector
-
0.013
39.8 (16 dBi)
10.0
0.06
5.8
GHz
90° sector
-
0.012
39.8 (16 dBi)
10.0
0.06
Table 77 ISEDC minimum safe distances, 40 MHz Channel Bandiwdth – PMP/PTP 450i, 3.5 GHz,
3.65 GHz, 5.4 GHz, and 5.8 GHz
Band
Antenna
P burst
(W)
P
(W)
G
(dBi)
S
(W/ m
2
)
d
(m)
3.5 GHz
90° sector antenna,
integrated
-
0.398
50.0 (17 dBi)
37.10
0.21
Panel, integrated
0.309
79 (19 dBi)
37.10
0.23
3.65
GHz
(Lower
Canada)
90° sector antenna,
integrated
-
0.020
50.0 (17 dBi)
6.99
0.10
3.65
GHz
(Upper
Canada)
90° sector antenna,
integrated
-
0.020
50.0 (17 dBi)
7.12
0.10
5.4 GHz 90° sector
-
0.019
40 (16 dBi)
9.39
0.08
5.8 GHz 90° sector
-
0.012
40 (16 dBi)
9.69
0.06