Chapter 2: System hardware
106
Caution
To provide adequate protection, all grounding cables must be a minimum size of
10 mm
2
csa (8AWG), preferably 16 mm
2
csa (6AWG), or 25 mm
2
csa (4AWG).
Table 79 :DC LPU and grounding kit part number
Cambium description
Cambium part number
DC LPU and Grounding Kit
C000000L114A
Cab le g r ound ing kit
Copper drop cable shields must be bonded to the grounding system in order to prevent lightning-strike
arcing (resulting in fire risk and damage to equipment).
One grounding kit (Cable grounding kit) is required for each grounding point on the cable. Order cable
grounding kits from Cambium Networks (LPU and grounding kit part number).
Figure 38 :
Cable grounding kit
Table 80 :Cable grounding kit part numbers
Cambium description
Cambium part number
Cable Grounding Kits For 1/4" And 3/8" Cable
01010419001
A nt ennas and ant enna cab ling
A nt enna r eq uir em ent s
Each connectorized ODU requires one external antenna (normally dual-polar).
For connectorized units operating in the USA or Canada 900 MHz, 4.9 GHz, 5.1 GHz, 5.2 GHz, 5.4 GHz or
5.8 GHz bands, choose external antennas which are recommended by Cambium Networks. Do not install
any other antennas.
Summary of Contents for PMP 450 Series
Page 92: ...Chapter 2 System hardware 92 Figure 29 MicroPoP Omni antenna implementation pattern Vertical...
Page 134: ...Chapter 3 System planning 134 Figure 51 Mast or tower installation...
Page 135: ...Chapter 3 System planning 135 Figure 52 Wall installation...
Page 136: ...Chapter 3 System planning 136 Figure 53 Roof installation...
Page 137: ...Chapter 3 System planning 137 Figure 54 GPS receiver wall installation...
Page 158: ...Chapter 3 System planning 158 Figure 61 cnMedusa Antenna...