Chapter 2: System hardware
Lightning protection unit (LPU) and grounding kit
Page
2-47
Table 54 LPU and grounding kit part number
Cambium description
Cambium part number
Aux ports LPU and Grounding Kit (One Kit Per End)
C000065L007B
When using LPUs on the Ethernet Ports of the 3 GHz 450m, a separate PoE power supply must be used
at the bottom of the mast to forward bias the diodes in the LPUs. This should be placed in the same
position as used in a PoE Ethernet Port. If this is not done, CRC errors will occur on the Ethernet
interface.
DC LPU and Grounding Kit
450m 3GHz LPUs provide transient voltage surge suppression for ODU installations. Each cable requires
two LPUs, one near the ODU and the other near the linked device, usually at the building entry point.
Table 55 DC LPU and grounding kit contents
Lightning protection units (LPUs)
LPU grounding point nuts and washers
EMC strain relief cable glands
U-bolts, nuts and washers for mounting LPUs
ODU to top LPU ground cable (M6-M6), bolt and
washers