Chapter 5: Installation
Installing ODU
Page
63
Installing ODU
Installing a 450 Platform Family AP
To install a 450 Platform Family AP, perform the following steps.
Procedure 5 Installing an AP
1
Begin with the AP in the powered-down state.
2
Choose the best mounting location for your particular application. Modules need not be
mounted next to each other. They can be distributed throughout a given site. However,
the 60° offset must be maintained. Mounting can be done with supplied clamps.
See
Installing external antennas to a connectorized ODU
for connecting an
external antenna to
PMP 450i Series, PMP 450 Series,
and
See
3
Align the AP as follows:
a.
Move the module to where the link will be unobstructed by the radio horizon and no
objects penetrate the Fresnel zone.
b.
Use a local map, compass, and/or GPS device as needed to determine the direction
that one or more APs require to each cover the intended 60° sector.
c.
Apply the appropriate degree of downward tilt.
d.
Ensure that the nearest and furthest SMs that must register to this AP are within the
beam coverage area.
4
Adjust the azimuth to achieve visual alignment, lock the AP in the proper direction and
downward tilt.
5
Attach the cables to the AP (See
Powering the AP/SM/BH for test configuration
6
Waterproof the cables (See section
Attaching and weatherproofing an N type connector
on page
).