3. Before starting the mechanical alignment, move the fine elevation adjuster 2/3 of the way across
the screw until the unit is sitting at approximately 0 degrees in elevation.
4. Move the fine azimuth adjuster to approximately the center of the available range and lock in
position.
5. Loosen the clamp which attaches the bracket to the pole until there is enough freedom to rotate
the unit in azimuth.
6. From behind the unit, using the sight to aim towards the remote node, rotate the unit until it is
approximately aligned in azimuth. Tighten the clamp.
7. While looking for the far node though the site, rotate the fine elevation adjuster until the alignment
is complete in the elevation plane. One turn of the adjustment wheel is equivalent to approximately
one degree of elevation. Lock the fine elevation adjuster screws in place.