background image

AP Management

Safety Notice

Configure Management PC

Specifications

Hardware Overview

Hardware Overview

Powering Up

The cnPilot e435W Access Point supports multiple modes of 

management:

 

Standalone:

 The Access Point can be managed directly from its GUI by 

selecting the ‘Configure’ tab on the menu, and setting up a wireless LAN.

 

Controller : 

The Access Point can be onboarded to cnMaestro network 

controller system, either on-premises or the cloud version at 

https://cloud.cambiumnetworks.com. 

For management from cloud please ensure the AP has connectivity to 

the internet. Connectivity can be verified using tools such as ping from 

the ‘Troubleshooting’ tab of the Access Point GUI. Connection status can 

be monitored from the AP dashboard.

1. 

2.

3..

Select Properties for the Ethernet port. In Windows it is found in 
Control Panel > Network and Internet > Network Connections > 
Local Area Connection.

IP Address Configuration:
Default IP address is received via DHCP.
cnPilot e435W will use a default static IP address of 192.168.0.1, If 
there is no DHCP server.

Default Login information
       - Username: admin

Management Protocols enabled by default –http or https (webpage 
management interface access), SSH (CLI management interface access). 

1. 

2.

3.

LED Color        

Amber                           Green                         Blue

Status 
Indicator

Access Point is 
powering up and 
Intitializing

Access Point is in 
service.

Access Point is 
managed with 
cnMaestro or 
autopilot.

Warning:

To prevent loss of life or physical injury, observe the following safety guidelines. In no 
event shall Cambium Networks be liable for any injury or damage caused during the 
installation of e435W platform. Ensure that only qualified personnel install.
Only use attachments/accessories specified by the manufacturer.

Electrical Safety Information

Do not substitute the power cord with one that is not the provided 
approved type. Never use an adapter plug to connect to a 2-wire outlet 
as this will defeat the continuity of the grounding wire. 

The equipment requires the use of the ground wire as a part of the safety 
certification, modification or misuse can provide a shock hazard that can 
result in serious injury or death.

Contact a qualified electrician or the manufacturer if there are questions 
about the installation prior to connecting the equipment.

Protective earthing is provided by Listed AC adapter. Building installation 
shall provide appropriate short-circuit backup protection.

Protective bonding must be installed in accordance with local national 
wiring rules and regulations.

1.

2.

3.

4.

a.

b.

c.

d.

e.

Compliance with manufacturer’s label for voltage, frequency, and current 
requirements. Connecting to a different power source than those specified may 
result in improper operation, damage to equipment or pose a fire hazard if the 
limitations are not followed.

There are no serviceable parts inside this equipment. Service should be 
provided only by a qualified service technician.

This equipment is provided with a detachable power cord which has an integral 
safety ground wire intended for connection to a grounded safety outlet.

 
      Be aware that the unit surfaces can become very hot to the touch so do not       
      handle the device when it is running for long periods of time. Turn off power    
      to the device first for a few minutes and then handle the unit carefully. 

FCC Compliance

Changes or modifications not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two conditions.
1.     This device may not cause harmful interference, and
2.    This device must accept any interference received, including interference that
       may cause undesired operation.

For product available in the USA/Canada market, only channel 1~11 can be operated. 
Selection of other channels is not possible.
This device is restricted for indoor use.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an 
uncontrolled environment. This equipment should be installed and operated with 
minimum distance 20 cm between the radiator & your body.

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one of the following measures:
-      Reorient or relocate the receiving antenna.
-      Increase the separation between the equipment and receiver.
-      Connect the equipment into an outlet on a circuit different from that to which
       the receiver is connected.
-      Consult the dealer or an experienced radio/TV technician for help.

IC Statement:

This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and 
(2) this device must accept any interference, including interference that may cause 
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils 
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) 
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en 
compromettre le fonctionnement. 

FCC Compliance

For product available in the USA/Canada market, only channel 1~11 can be operated. 
Selection of other channels is not possible.
Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11 
peuvent être exploités. Sélection d'autres canaux n'est pas possible.

The device for operation in the band 5150–5250 MHz is only for indoor use to reduce the 
potential for harmful interference to co-channel mobile satellite systems.
les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement 
pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux 
systèmes de satellites mobiles utilisant les mêmes canaux.

For indoor use only.
Pour une utilisation en intérieur uniquement.

IMPORTANT NOTE:
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an 
uncontrolled environment. This equipment should be installed and operated with 
minimum distance 20 cm between the radiator & your body.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies 
pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un 
minimum de 20 cm de distance entre la source de rayonnement et votre corps.

This radio transmitter has been approved by FCC to operate with the antenna types 
listed below with the maximum permissible gain and required antenna impedance for 
each antenna type indicated. Antenna types not included in this list, having a gain 
greater than the maximum gain indicated for that type, are strictly prohibited for use 
with this device.

Antenna Information: Five single-band antenna, Gain 2.98/4.05dBi

RoHS/WEEE Compliance

Online Resources

User Guide and software downloads:
https://support.cambiumnetworks.com/files/e435W/

Support:
http://www.cambiumnetworks.com/support/

Contact us:
http://www.cambiumnetworks.com/support/contact-support/

Caring for the Environment: RoHS/WEEE

European Directive 2002/96/EC requires that the equipment bearing this symbol on 
the product and/or its packaging must not be disposed of with unsorted municipal 
waste. The symbol indicates that this product should be disposed of separately from 
regular household waste streams. It is your responsibility to dispose of this and 
other electric and electronic equipment via designated collection facilities 
appointed by the government or local authorities. Correct disposal and recycling will 
help prevent potential negative consequences to the environment and human 
health. For more detailed information about the disposal of your old equipment, 
please contact your local authorities, waste disposal service, or the shop where you 
purchased the product.

CE Marking

CE marking on this product represents the product is in compliance with all 
directives that are applicable to it.

With 802.3af/at 
PSE 

With 802.3af/at 
PSE switch 

With Injector

LAN / Computer

To AC 
outlet

To AC 
outlet

LAN / Computer

With 48V Power 
adapter

48V Power adapter

Cambium 30W 
injector

Kensington 

Lock Slot 

Reset 

Button 

Eth1/

PoE IN 

PASS

THRU 

PASS THRU 

48V/ 1A

ETH2 

ETH3 

ETH4/

PoE OUT 

Reset

 -  To restart, press and hold Reset.

              To restore to factory default settings, press and hold Reset for more than                

              10 seconds.  

Eth1/

PoE IN

 - Gigabit Ethernet port used to connect the power. It should be connected 

               to the LAN and DHCP server.  

Eth2/

Eth3

    -  Spare gigabit Ethernet ports for connecting additional network devices.

Pass 

Thru 

   -  Are electrically connected internally so that in-wall wired non-Ethernet    

               connectivity to a device in the room can be connected easily through  

 

               e435W port on the back to the corresponding pass thru port on the  

 

               bottom edge of the AP. If desired, the Eth1/PoE IN port can be jumpered   

               with a short Ethernet cable and the Pass Thru port on the bottom edge    

               can be used as the main LAN/PoE IN port.

 

Ethh4/

PoE OUT

  -  Provides DC power to a secondary device and is    

 

                    802.3af compliant. It detects the device power and connectivity                  

 

   needs dynamically. This port can also be used as a standard     

 

   Gigabit networking data only port.

 

DC

Power

      -  e435W can be powered with a 48V/1A power adapter as an                           

 

   alternate to PoE. The power jack is located on the bottom edge of  

 

   the device next to the Eth4/PoE OUT LAN port. 

Kensington 

Lock Slot

  - The slot on the side of e435W that can be used to secure the unit 

                     to deter theft with a Kensington Lock device.