Do not install the product with unstable brackets, or installed on fragile mount surfces. 

• 

This product shall be used in compliance with local laws and regulation. 

• 

Please avoid using chemical 

or aerosol cleaning fluids to clean the product. Use a clean cloth 

slightly moistened with water. 

• 

This product contains no parts repairable by the users. Contact CaMate for services.   

• 

Power off the Illuminator as soon as smoke or unusual odors are detected.

• 

Do not place the Illuminator on unsteady surfaces.

• 

Replacing or failing to properly install the waterproof components, e.g., cables or cable glands, 

will void our IP67 warranty.

• 

Refer to your datasheet for the operating temperature.

• 

Do not touch the Illuminator during a lightning storm.

IMPORTANT:  

Class III luminaires

Do not stare at the operating light source. 

This marking indicates that this product should not be disposed with other household 

wastes throughout the EU. To prevent possible harm to the environment or human health 

from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse 

of material resources. To return your used device, please use the return and collection 

systems or contact the retailer where the product was purchased. They can take this 

product for environmental safe recycling.

RISK GROUP 3

WARNING IR emitted from this product,
Do not look at operating lamp.

IR illuminators RISK GRORP 3 / WARNING IR emitted from this product. / Avoid eye exposure. Use 

appropriate shielding or eye protection. Do not look at operating lamp.

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Summary of Contents for CA80 Series

Page 1: ...Installation Guide CA80 Series Vari Angle IR Illuminator Rev 1 0 QIG Part no L625000100G Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...

Page 2: ...closer than 2 5 m is not expected The external flexible cable or cord of this luminaire cannot be replaced if the cord is damaged the luminaire shall be destroyed The light source of this luminaire i...

Page 3: ...ring a lightning storm IMPORTANT Class III luminaires Do not stare at the operating light source This marking indicates that this product should not be disposed with other household wastes throughout...

Page 4: ...6mm 5 3 61 5mm 2 4 164 6mm 6 5 59 5mm 2 3 43mm 1 7 43mm 1 7 59mm 2 3 32mm 1 3 Mechanical Drawings 134 M6x1 4 64 29 3 8 2 30 82 Standard Small U bracket Available from A1 Security Cameras www a1securit...

Page 5: ...racket Optional mounting points for U bracket Light sensor Combo cable Dehumidifier membrane Reserved Mounting holes Unit Weight 2 1KG Max Project Area 34684 7mm2 160mm 6 3 220mm 8 7 Available from A1...

Page 6: ...pressing this button for 2 seconds The control is automatically locked after being idle for 5 mins LED status The button toggles the LED indicators on or off The LEDs are only visible on the non IR il...

Page 7: ...h and adjust the U bracket to your needs at the installation site It is highly recommended that the illuminator should be installed at a position higher than 3 meters from the ground IMPORTANT Availab...

Page 8: ...always at the Widest angle Refer to the tables below for the configurable IR light beam angles and the definitions of the remote controller buttons Each button changes to a preset beam angle Width Dis...

Page 9: ...e e g under a hanging roof You can use the alignment sticker and start drilling a hole on the roof Apply the included grip sticker to the U bracket Available from A1 Security Cameras www a1securitycam...

Page 10: ...rs are recommended Secure the U bracket to it such as securing it using the bolt on a threaded pole Secure the illuminator to bracket using the hex socket screws Available from A1 Security Cameras www...

Page 11: ...the camera s field of view If necessary adjust the beam angle again Turn the illuminator toward the FOV of the partner camera shift the tilt angle and then tighten the screw and the rear cover to secu...

Page 12: ...lose to GND LED on Wet contact Logic level 1 4V 40 V LED off Logic level 0 0 8V MAX LED on DI Yellow 26AWG Ground DO Purple 26AWG Light sensor status output 1 Open Day 2 Short Night 300 lux for IR ON...

Page 13: ...lluminator On Off control is triggered by camera or other alarm system Users can decide using the appropriate dry wet contacts depending on wiring condition DI Green TTL voltage DI Yellow TTL voltage...

Page 14: ...status output 1 Open Day 2 Short Night lower than 300 lux for IR to turn ON Stand alone illuminator mode This mode means that the illuminator s On Off control is triggered by its light sensor in the...

Page 15: ...15 This page is intentionally left blank Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...

Page 16: ...16 This page is intentionally left blank Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com...

Reviews: