P r e - O p e r a t i o n   P r e p a r a t i o n

1. Verify 

Luna HD

 software and hardware setup.

2. Clean 

Luna HD

 (first time use) as necessary.

3.  Install a new Camera Sheath on the handpiece for each patient. 

IMPORTANT

Make sure to align the optically clear section of the sheath 

with the camera lens by facing the camera/light source 

section of the handpiece down toward the paper layer.

Camera Sheath Installation - 

1  Insert the handpiece tip between the second 

and third layers with the camera/light facing 
towards the paper layer.  

See A and B

2. Completely insert tip until it is fully into the 

narrow section of the sheath.

3.  Squeeze the illuminated tip to ensure that the 

optically clear area of the Camera Sheath is 
flat against the lens tip.  

See C.

4. Peel away and discard the top plastic layer 

and the bottom paper layer.  

See D

.

Step 1 and 2

Step 4

Step 3

2

The Camera Sheath must be used for only one patient and disposed 

of properly in accordance with local code.

Surface Cleaning Instructions:

Clean the handpiece following each patient use.  The cleaning instructions must be followed carefully to prevent damage to the 
camera housings, and internal components.  Cleaning products containing active ingredients listed in the Product Care Guidelines are 
prohibited for use with 

Luna HD

.  These chemicals can cause damage to the camera and could void the warranty.

6

5

1.  Disconnect the USB cable.  Remove the Camera Sheath and dispose in accordance with local code.
2.  Moisten a cloth with warm water and remove any excessive moisture from the cloth before wiping the handpiece.
3.  Wipe outer camera body with the moist cloth to ensure no pooling of water surrounds capture switch, ON/Standby button or USB 

connection. 

4.  The window lens may be cleaned with a cotton swab which is moistened with 70% isopropyl alcohol.
5.  Allow the handpiece sufficient time to air dry before applying a new Camera Sheath, or storing the camera prior to the next use.

Do not autoclave the Camera Handpiece

Do not apply excessive pressure when wiping; do not scrub.

Do not rinse or immerse the handpiece in liquids.

Do not spray the handpiece directly with liquids .

O p e r a t i n g   P r o c e d u r e

Important: Patient Safety - 

Make sure you are using a new Camera Sheath for each patient.

7

 

The PDF version of Operator’s Manual for Luna HD is included on the CD.  Also included are USB Device Drivers, TWAIN 

Interface, Demonstration Program, Software Installation and Configuration Guide and Adobe Acrobat Reader  

 

Authorized imaging software, purchased from your dealer or other company, must be installed on the computer in order 

to operate Luna HD.

 

Make sure that the computer meets all requirements necessary to support the Luna HD. See Minimum Computer System 

Requirements in the Operator’s  Manual.

1.  Start the imaging software. 
2.  Press the ON/Standby button to activate camera.
3.  Set the red dot of the focusing ring to the desired view setting mark. 

The red dot may be adjusted between the marks as desired.

4.  Position the camera lens window over the object to be imaged and 

view the image on monitor.  Make small adjustments to the focusing 
ring position as needed to adjust image clarity.  

5.  Press and release the handpiece top switch to freeze the displayed 

video on the monitor. If image is not suitable, proceed to step 6.  
When image is suitable, perform to step 7.

6.  Press and release the top switch again to unfreeze the displayed image 

and return to a live video display.  Return to step 5 to freeze video.

7.  Press and release the handpiece bottom switch  to save the frozen 

image to the computer hard drive and return to a live video display. 

8.  Repeat steps 3 through 7 as necessary. 
9.  Press the ON/Standby button to turn the camera OFF.  

ON/

Standby

Top 

Button

Bottom 

Button

a

d

b

c

Focusing 

Ring

Handpiece 

Connector

a.  50 to 300 mm  Face - Smile - Arch
b.  15 mm 

Intraoral Mouth Tour

c.  8 mm 

Single Tooth Intraoral

d.  2 mm 

Macro view

Focusing Ring Settings

b

c

d

a

Scan QR Code for 

more about Luna HD.

Camera

Sheath

Camera

Handpiece

Light

Plastic

Layer 1

Plastic

Layer 2

Plastic

Layer 3

Squeeze

Plastic

Layer 1

Paper

Layer

A

B

C

D