Cam Scan CS-PTZ8800 Installation & Operating Manual Download Page 12

22

23

ALARM MENU

< NEAR / RIGHT   

  ALARM  NO > 

ALARM    NO  :  01   UNDEFINE

LABEL  :       
PRESET NO.  : XX

SAVE               CLR               BACK             EXIT

ALARM MENU

< NEAR / RIGHT   

  ALARM  LABEL > 

ALARM    NO  :  01   DEFINE

LABEL  :       

PRESET NO.  : XX

SAVE               CLR               BACK             EXIT

The Alarm function means that the camera moves to the programmed Preset position by the Alarm trigger.
Maximum 8 Alarm functions are toured in order.

4. 1. 7   Alarm

MAIN MENU

< NEAR / RIGHT   

  PRESET >

MOTION        

DOME            

CAMERA       

CLEAR           

PTZ RESET    

BACK                             EXIT

(1) Select the Alarm number
     Alarm 01 : Defined Alarm number / 01 : Undefined Alarm number

     Move :                Select :

NEAR

(2) Set the Alarm Label

     Move :                Select :     or     or               Delete :             or

TELE

JOYSTICK

WIDE

JOYSTICK

     It’s available to set the desired label, displayed on the executing screen of Alarm.

     After the label is set, push the NEAR button to exit. 

ALARM  LABEL EDIT ( 01 )

< DELETE   

 WIDE

< STORE    

  TELE 

BACK     

    NEAR       >

MOVE    

    JOYSTICK >

LABEL  :  ALARM  01

   0  1  2  3  4 5  6  7  8 9  (

) A  B  C D E F G H  I  J  K

L M N O P Q R S T U V W

X Y  Z  .  /  ,  +  -  =  <  >  

ALARM SELECT

< SEL  

  NEAR    /    MOVE     JOYSTICK >

01

02      

07

08      

03  

04

05

06

ALARM MENU

< NEAR / RIGHT   

  SELECT PRESET > 

ALARM    NO  :  01   DEFINE
LABEL  :       

PRESET NO.  : 01

SAVE               CLR               BACK             EXIT

(3) Define the Preset position with Alarm trigger
    

① 

Select the “Preset No”

or

NEAR

   ② 

Move and set the position       

③ 

Set & Back

NEAR

(4) “Save” above setting Alarm data to the memory.

(5) “CLR” means above setting Alarm data will not be
      saved and be cleared.

(6)  “BACK” means it goes back to the previous
        menu :Motion. 

(7) “EXIT” means it goes out of MENU

PRESET SELECT 

001

  002  003  004  005  006

007  008  009  010  011  012
013  014  015  016  017  018
019  020  021  022  023  024
025  026  027  028  029  030
031  032  033  034  035  036
037  038  039  040  041  042
043  044  045  046  047  048
049  050  051  052  053  054

<SEL 

NEAR /MOVE & JOYSTICK>

ALARM MENU

< NEAR / RIGHT   

  SELECT PRESET > 

ALARM    NO  :  01   DEFINE
LABEL  :       
PRESET NO.  : 01

SAVE

               CLR               BACK             EXIT

MOTION MENU

< NEAR / RIGHT   

  ALARM >

PRESET      

GROUP       

TOUR          

SCAN  

        

PATTERN    

ALARM      

AREA          

PRIVACY    

BACK                             EXIT

Summary of Contents for CS-PTZ8800

Page 1: ...INSTALLATION OPERATING MANUAL Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use The design and specifications are subje...

Page 2: ...uld be done only by qualified personnel and conform to all local codes Installation should be done in a place strong enough to hold it Use only installation methods and materials capable of supporting...

Page 3: ...LCO D PELCO P WTX EZP NC NC NC NC PROTOCOL 4 5 6 OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON ON ON OFF OFF ON OFF ON ON ON OFF ON ON ON 2400 4800 9600 19200 38400 57600 115200 NC BAUDRATE 7 OFF ON RS 422...

Page 4: ...m to all local codes Be sure to switch the camera off before installation is completed Do not install the camera near the air outlet of an air conditioner Before installation set the dome system with...

Page 5: ...umber Move Select NEAR 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 0...

Page 6: ...It allows detailed settings for the preset Select the Focus menu or NEAR Move and set the Focus Menu 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z POSITION 000 0 000 0 EXIT F...

Page 7: ...036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 SEL NEAR MOVE JOYSTICK TOUR LABEL EDIT 01 DELETE WIDE STORE TELE BACK NEAR MOVE JOYSTICK LABEL TOUR 01 0 1 2 3 4 5 6 7 8 9...

Page 8: ...FOCUS AUTO SAVE CLR BACK EXIT SCAN MENU NEAR RIGHT END POS SCAN NO 01 DEFINE LABEL SCAN 01 START POS 000 0 000 0 END POS 000 0 SPEED 60 DWELL 02 FOCUS AUTO SAVE CLR BACK EXIT STRAT POSITION EXIT FOCUS...

Page 9: ...60 DWELL 02 FOCUS AUTO SAVE CLR BACK EXIT It adjusts the moving speed from 1 63 steps Focus can be set Auto or Manual 6 Set the Dwell Time Increase or Decrease or TELE JOYSTICK WIDE JOYSTICK Dwell ti...

Page 10: ...N RECORD 2 Set the Pattern Label Move Select or or Delete or TELE JOYSTICK WIDE JOYSTICK It s available to set the desired label displayed on the executing screen of Pattern After the label set push N...

Page 11: ...G H I J K L M N O P Q R S T U V W X Y Z AREA MENU MOVE NEAR JOYSTICK AREA NO 01 DEFINE LABEL START PAN POS 000 0 STOP PAN POS 000 0 SAVE CLR BACK EXIT AREA MENU MOVE NEAR JOYSTICK AREA NO 01 DEFINE LA...

Page 12: ...K LABEL ALARM 01 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z ALARM SELECT SEL NEAR MOVE JOYSTICK 01 02 07 08 03 04 05 06 ALARM MENU NEAR RIGHT SELECT PRESET ALARM NO 01 DEF...

Page 13: ...d Alarm number 01 Undefined Alarm number Move Select NEAR 2 Set the Privacy Zone Position Move Select or or Delete or TELE JOYSTICK WIDE JOYSTICK It s available to set the desired position and size of...

Page 14: ...RIGHT PARK TIME TIME MIN OFF FUNCTION NONE NUMBER XX BACK EXIT 1 Set the park Time OFF 10sec 10 min 2 Select the function which will be back after the above set time 3 Select the appointed function s...

Page 15: ...IGHEST Output the Max IR light HIGH Output the hight level of IR light LOWEST Out put the Min IR light LOW Output the low level of IR light MOTION SAVE CAM DATA SAVE DOME DATA SAVE ALL DATA SAVE MOTIO...

Page 16: ...lumination 0 5 10 5 ICR CHG LUX 8 WIPER MODE Factory default is 2 LUX factory default is OFF Select or Set ON Set OFF NEAR NEAR 6 IR CONT TYPE Factory default is OFF 2 HEATER ON TIME DOME MENU DATA BA...

Page 17: ...50 C 40 C CURRENT TEMPER 50 40C NEAR RIGHT FAN OFF BACK DOME MENU HEATER ON TEMP HEATER ON TIME HEATER OFF TEMP FAN ON TEMP FAN OFF TEMP 5 C 30 MIN 15 C 50 C 40 C CURRENT TEMPER 50 40C Set the temerat...

Page 18: ...Humidity 0 to 90 non condensing Fan operate 50 C on 40 C off Heater operate 5 C on 15 C off Preset 255 points less than 0 1 accuracy Tour 8 programmable Pattern 4 patterns for 60 second Group 6 group...

Page 19: ...36 37 7 CONFIGURATION 7 1 Connecting to Keyboard with DVR...

Reviews: