3.4. Sensors
· Ultrasonic transducers (4x)
· Sample rate: 0.1 Hz to 20 Hz
3. Technical specifications
(continuation)
ULP 485 has to be connected as is shown below:
3.3. Power
· 3,3 -24 V
Wind speed
Range: 0 - 40 m/s
Accuracy: ±0.1 m/s at 10m/s
Wind direction
Range: 0 - 360°
Accuracy: ± 1°
3.5. Wind
information
· Wind speed
· Wind direction
Lateral and inferior female thread. It can be
moun
-
ted either on a plate (inferior screws) or on
a tube (lateral screws)
3.6. Easy mount
· 3xM4 lateral female thread
· 3xM4 inferior female thread
Brown
VCC (Power +)
White
GND (Power -)
Green
DATA (A +)
Yellow
DATA (B -)
The ULP485 has been designed to avoid any
mechanical parts to maximize reliability and
minimize maintenance.
The transducers communicate between themsel
-
ves two by two using ultrasonic range waves. Each
couple of transductors calculates the signal delay
and gets information about both, wind direction
and wind speed.
ULTRASONIC ULP 485
User manual
ULTRASONIC ULP 485
User manual
1-RS485 continuous output
2-POLL output
3-Any other ptrotocol under demand.
NMEA0183
2400 to 115200 bauds
3,3-24V
Data interface
Data format
Baudrate
Voltage range
Image 1. Serial number/Control quality label
Image 3. North mark.
Image 4. Screw holes position .
Image 5. Cable connections.
Images 6.
3xM4 lateral female thread
Images 7.
3xM4 inferior female thread