AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 277 of 402
8.9.4
System Configuration Commands
Query Format
SYSTem:MAXKVA?
Description
Returns maximum available kVA output capability of the power
source. Example for 3150AFX model = 15.0000
Returned Data Format
<nr2>
Query Example
SYST:MAXKVA?
15.000
Query Format
SYSTem:MAXCURRent?
Description
Returns maximum available RMS or DC output current capability of
the power source. Example for 3150AFX model = 41.6667.
Returned Data Format
<nr2>
Query Example
SYST:MAXCURR?
41.6667
Query Format
SYSTem:MAXVOLTage?
Description
Returns maximum available RMS or DC voltage output capability of
the power source. Example for 3150AFX model = 300.
Returned Data Format
<nr1>
Query Example
SYST:MAXVOLT?
300
Command Syntax
SYSTem:COMPatible
Description
Sets Pacific Power Source UPC controller compatibility mode. This
mode allows use of the power source with legacy software.
Parameters
< 0 | DISABLE | 1 | UPC >
Parameter Format
Example
SYST:COMP UPC
Query Format
SYSTem:COMPatible?
Returned Data Format
<b>
Query Example
SYST:COMP?
1
Query Format
SYSTem:HWREVision?
Description
Returns the hardware revision letter of the power source
Returned Data Format
<cr>
Query Example
SYST:HWREV?
A