SECTION 4 FLOW
®
making
since 1986
water work
C. MASTER VALVE
This section of the controller allows you to select from
two types of master valves available:
•
Normally
Open
•
Normally
Closed
From the FLOW METER, MASTER VALVE & PUMP
SETUP screen (Figure 4.1).
1.
Press the
MASTER VALVE
Menu
key.
The TYPE OF MASTER VALVE screen is displayed
(Figure 4.9).
The MASTER VALVE is NORMALLY CLOSED
TYPE OF MASTER VALVE
Figure 4.9
The Master Valve default setting is for a normally
closed Master Valve. There are two (2) settings,
•
NORMALLY CLOSED:
A normally closed
master Valve is in the closed position until
voltage is applied to open it.
•
NORMALLY OPEN:
A normally open Master
Valve is in the open position until voltage is
applied to close it.
Note:
Be sure to select the correct type of Master
Valve installed, if it is incorrect the Master Valve will
close whenever a station is irrigated and no water will
flow when a valve is turned on
.
2.
Press the
BACK
key to return to the
FLOW METER, MASTER VALVE, &
PUMP SETUP screen (shown Figure
4.1).
THIS CONCLUDES THE MASTER VALVE
SECTION
D. PUMP
If you are using a pump for any one of your valves you
will have to set the controller to recognize that there is
a pump in use and on which program it will be used
on.
From the FLOW METER, MASTER VALVE & PUMP
screen (Figure 4.1).
1.
Press the
PUMP
Menu key.
The WHICH PROGRAMS USE THE PUMP screen is
displayed (Figure 4.10).
PROG A . . . . . . . . . . . . . . . . . . . . . . . YES
PROG C . . . . . . . . . . . . . . . . . . . . . . . YES
PROG D . . . . . . . . . . . . . . . . . . . . . . . YES
PROG E . . . . . . . . . . . . . . . . . . . . . . . YES
DRIP 1 . . . . . . . . . . . . . . . . . . . . . . . YES
PROG B . . . . . . . . . . . . . . . . . . . . . . . YES
DRIP 2 . . . . . . . . . . . . . . . . . . . . . . . YES
WHICH PROGRAMS USE THE PUMP
if you would like to use the pump
For each program, select YES
Figure 4.10
2.
Press the blue
ARROW
keys to
move the cursor to the Program
desired.
The default setting is set to YES on all programs. This
means that the controller’s pump output will be
activated whenever a station on any program is
activated.
3.
Press the
PLUS
or
MINUS
keys to
change any Program.
Note:
If the Pump Output Enabled setting is set to NO
on a program, the pump output will not activate when a
station on that program is activated.
4.
Press the
BACK
key to return to the
Flow Meter, Master Valve & Pump
screen (See figure 4.1).
THIS CONCLUDES THE PUMP
SECTION