INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR

SERIES OKA  –  INFRARED RADIANT HEATERS

FIRE/EXPLOSION  HAZARD  WARNING  -  During  operation,  take  precautions  to  ensure  that

combustible materials are always kept at a safe distance from the radiant energy.  This heater is

not  intended  for  use  in  hazardous  areas  where  flammable  vapours,  gases  or  liquids  or  other

combustibles are present.  Remember that objects placed under an infrared heater can take a while

to reach stabilized temperatures.  If you are unsure of the suitability of the heater for the intended

application, check with the factory for recommendations.  Failure to comply can result in personal

injury and/or property damage.

DESCRIPTION

1.0

The OKA radiant heater is suitable for process heating in

non-hazardous areas protected from rain, snow or splashing, where
heating element temperatures in excess of 1382°F(750°C) will not
present the risk of fire or explosion.  This heater is not intended for
use in comfort heating applications.

2.0

The OKA heater is available with metal sheathed, quartz

lamp  or  quartz  tube  heating  elements.  Use  heaters  with  metal
sheathed elements where there is heavy vibration or mechanical
shock.  Quartz tube or quartz lamp elements are very fragile and
require extreme care in handling.  Heaters utilizing quartz tubes or
quartz lamps are unsuitable for applications in locations where the
risk of heavy vibration or mechanical shock exists.

3.0

To  avoid  damage  in  transit,  heaters  with  quartz  lamp  or

quartz tube elements are shipped with the elements not installed in
the fixture.

4.0

A  minimum  of  handling  of  the  quartz  sheath  is

recommended since any type of contamination on the sheath may
reduce service life.

INSTALLATION

The system designer is responsible for

the  safety  of  this  equipment  and

adequate back-up controls and safety

devices must be installed.  Failure to

comply could result in personal injury

and/or property damage.

Heaters  must  be  wired  by  qualified

personnel  in  compliance  with  local

codes.

5.0

Verify that the nameplate voltage and wattage are suitable

for use on the available electrical power supply.  Do not connect
the heater to an electrical supply voltage other than shown on the
product label.

For metal sheathed heaters, insulation

contamination 

or 

moisture

accumulation  can  cause  fault  to  the

element sheath generating arcing and

releasing molten metal.  Install proper

ground  fault  protection  to  prevent

personal  injury  and/or  property

damage.

6.0

When  mounting,  maintain  a  minimum  clearance  to

combustibles  of  15”(381  mm)  at  sides,  10”(254  mm)  at  top  and
12”(305 mm) at ends.

Heaters with quartz tube or quartz lamp

type heating elements are suitable for

horizontal mounting only.  Heaters with

metal sheathed heating elements can

be mounted in any desired position.

7.0

For short circuit protection, heaters must be installed with

proper  fast  acting  fuses  or  breakers  as  close  as  possible  to  the
amperage draw of the unit(s), in compliance with the local electrical
codes.

380 mm

[15”]

300 mm

[12”]

250

 m

m

[10”

]

FIG. 1  –  MOUNTING CLEARANCES

CCI Thermal Technologies Inc.  2721 Plymouth Drive, Oakville, ON L6H 5R5  Tel. (905) 829-4422  Fax (905) 829-4430

www.ccithermal.com

ISO 9001:2000

MI148 REV.11.01

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR

SERIES OKB, OKD & OKH – INFRARED RADIANT HEATERS

ISO 9001

FIRE/EXPLOSION HAZARD WARNING - During operation, take precautions to ensure that combustible materials 
are always kept at a safe distance from the radiant energy. This heater is not intended for use in hazardous areas 

where flammable vapours, gases or liquids or other combustibles are present. Remember that objects placed under 

an infrared heater can take a while to reach stabilized temperatures. If you are unsure of the suitability of the heater for 

the intended application, check with the factory for recommendations. Failure to comply can result in personal injury 

and/or property damage.

1.0 

The OKB, OKD & OKH radiant heaters are suitable for 

comfort heating use in non-hazardous areas protected from 
rain, snow or splashing, where heating element temperatures 

in excess of 1382°F(750°C) will not present the risk of fire or 

explosion. The heater does not present a safety hazard when 
it is installed, operated and maintained in accordance with 
these instructions.

2.0 

The heaters are available with metal sheath, quartz 

lamp or quartz tube heating elements. Use heaters with 
metal sheathed elements where there is heavy vibration or 
mechanical shock. Quartz tube or quartz lamp elements are 
very fragile and require extreme care in handling. Heaters 
utilizing quartz tubes or quartz lamps are unsuitable for 
applications in locations where the risk of heavy vibration or 
mechanical shock exists.

3.0

 To avoid damage in transit, heaters with quartz lamp 

or quartz tube elements are shipped with the elements not 

installed in the fixture.

4.0

 A minimum of handling of the quartz sheath is 

recommended since any type of contamination on the sheath 
may reduce service life.

DESCRIPTION

The system designer is responsible for 
the safety of this equipment and adequate 
backup controls and safety devices must be 
installed. Failure to comply could result in 
personal injury and/or property damage. 

Heaters must be wired by qualified personnel 

in compliance with local codes.

5.0 

Verify that the nameplate voltage and wattage are suitable

for use on the available electrical power supply. Do not connect
the heater to an electrical supply voltage other than shown on 
the product label.

6.0 

Minimum space clearances from combustibles, when 

heaters are horizontally mounted and installed, as listed in 
Table 1 following.

DESCRIPTION

MI146 REV.10   Page 1 of 3

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR

SERIES OKA  –  INFRARED RADIANT HEATERS

FIRE/EXPLOSION  HAZARD  WARNING  -  During  operation,  take  precautions  to  ensure  that
combustible materials are always kept at a safe distance from the radiant energy.  This heater is
not  intended  for  use  in  hazardous  areas  where  flammable  vapours,  gases  or  liquids  or  other
combustibles are present.  Remember that objects placed under an infrared heater can take a while
to reach stabilized temperatures.  If you are unsure of the suitability of the heater for the intended
application, check with the factory for recommendations.  Failure to comply can result in personal
injury and/or property damage.

DESCRIPTION

1.0

The OKA radiant heater is suitable for process heating in

non-hazardous areas protected from rain, snow or splashing, where

heating element temperatures in excess of 1382°F(750°C) will not

present the risk of fire or explosion.  This heater is not intended for

use in comfort heating applications.

2.0

The OKA heater is available with metal sheathed, quartz

lamp  or  quartz  tube  heating  elements.  Use  heaters  with  metal

sheathed elements where there is heavy vibration or mechanical

shock.  Quartz tube or quartz lamp elements are very fragile and

require extreme care in handling.  Heaters utilizing quartz tubes or

quartz lamps are unsuitable for applications in locations where the

risk of heavy vibration or mechanical shock exists.

3.0

To  avoid  damage  in  transit,  heaters  with  quartz  lamp  or

quartz tube elements are shipped with the elements not installed in

the fixture.

4.0

A  minimum  of  handling  of  the  quartz  sheath  is

recommended since any type of contamination on the sheath may

reduce service life.

INSTALLATION

The system designer is responsible for
the  safety  of  this  equipment  and
adequate back-up controls and safety
devices must be installed.  Failure to
comply could result in personal injury
and/or property damage.

Heaters  must  be  wired  by  qualified
personnel  in  compliance  with  local
codes.

5.0

Verify that the nameplate voltage and wattage are suitable

for use on the available electrical power supply.  Do not connect

the heater to an electrical supply voltage other than shown on the

product label.

For metal sheathed heaters, insulation
contamination 

or 

moisture

accumulation  can  cause  fault  to  the
element sheath generating arcing and
releasing molten metal.  Install proper
ground  fault  protection  to  prevent
personal  injury  and/or  property
damage.

6.0

When  mounting,  maintain  a  minimum  clearance  to

combustibles of 15”(381 mm) at sides, 10”(254 mm) at top and

12”(305 mm) at ends.

Heaters with quartz tube or quartz lamp
type heating elements are suitable for
horizontal mounting only.  Heaters with
metal  sheathed  heating  elements  can
be mounted in any desired position.

7.0

For short circuit protection, heaters must be installed with

proper fast acting fuses or breakers as close as possible to the

amperage draw of the unit(s), in compliance with the local electrical
codes.

380 mm

[15”]

300 mm

[12”]

250

 m

m

[10”

]

FIG. 1  –  MOUNTING CLEARANCES

CCI Thermal Technologies Inc.  2721 Plymouth Drive, Oakville, ON L6H 5R5  Tel. (905) 829-4422  Fax (905) 829-4430

www.ccithermal.com

ISO 9001:2000

7.0 

For chain mounting, install eye bolts supplied in the 

¼-20 drilled and tapped holes located at the top of the cast 
aluminumend plates. Use the locking nut to secure the eye bolt 
in the casting at the preferred location. Fasten the chains to the 

eye bolts and suspend the fixture from the ceiling ensuring that 

the minimum clearances shown in Table 1 are maintained.

MI148 REV.11   Page 1 of 3

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR

SERIES OKB, OKD & OKH  –  INFRARED RADIANT HEATERS

FIRE/EXPLOSION  HAZARD  WARNING  -  During  operation,  take  precautions  to  ensure  that

combustible materials are always kept at a safe distance from the radiant energy.  This heater is

not  intended  for  use  in  hazardous  areas  where  flammable  vapours,  gases  or  liquids  or  other

combustibles are present.  Remember that objects placed under an infrared heater can take a while

to reach stabilized temperatures.  If you are unsure of the suitability of the heater for the intended

application, check with the factory for recommendations.  Failure to comply can result in personal

injury and/or property damage.

DESCRIPTION

1.0

The  OKB,  OKD  &  OKH  radiant  heaters  are  suitable  for

comfort heating use in non-hazardous areas protected from rain,

snow or splashing, where heating element temperatures in excess

of 1382°F(750°C) will not present the risk of fire or explosion.   The

heater does not present a safety hazard when it is installed, operated

and maintained in accordance with these instructions.

2.0

The heaters are available with metal sheath, quartz lamp

or quartz tube heating elements.  Use heaters with metal sheathed

elements  where  there  is  heavy  vibration  or  mechanical  shock.

Quartz tube or quartz lamp elements are very fragile and require

extreme care in handling.  Heaters utilizing quartz tubes or quartz

lamps are unsuitable for applications in locations where the risk of

heavy vibration or mechanical shock exists.

3.0

To  avoid  damage  in  transit,  heaters  with  quartz  lamp  or

quartz tube elements are shipped with the elements not installed in

the fixture.

4.0

A  minimum  of  handling  of  the  quartz  sheath  is

recommended since any type of contamination on the sheath may

reduce service life.

INSTALLATION

The  system  designer  is  responsible  for  the

safety of this equipment and adequate back-

up  controls  and  safety  devices  must  be

installed.  Failure  to  comply  could  result  in

personal injury and/or property damage.

Heaters must be wired by qualified personnel

in compliance with local codes.

5.0

Verify that the nameplate voltage and wattage are suitable

for use on the available electrical power supply.  Do not connect

the heater to an electrical supply voltage other than shown on the
product label.

6.0

Minimum  space  clearances  from  combustibles,  when

heaters are horizontally mounted and installed, as listed in Table 1
following.

7.0

For chain mounting, install eye bolts supplied in the ¼-20

drilled and tapped holes located at the top of the cast aluminum

end plates.  Use the locking nut to secure the eye bolt in the casting

at the preferred location.  Fasten the chains to the eye bolts and

suspend  the  fixture  from  the  ceiling  ensuring  that  the  minimum

clearances shown in Table 1 are maintained.

UL

CSA

Table 1

OKB, OKD & OKH

OKB

OKD &

H

K

O

L

N

C

L

S

U

A.   From the nearest w all

24"(610 mm)

15"(380mm) 10"(254mm)

B.   From end of heater to w all

24"(610 mm)

12"(305mm) 39"(1000mm)

C.   From the ceiling

24"(610 mm)

15"(380mm) 15"(380mm)

D.   From the Floor

72"(1830 mm) 96"(2400 mm)

E.   Betw een heaters

36"(915 mm)

8.0

For rod mounting ¼”-20 threaded rods of suitable length

are to be installed in place of the eye bolts as in paragraph 7.0

above.

9.0

If flush mounting on a non-combustible surface, be sure to

slot  the  mounting  holes  (5/16”  x  ½”  hole)  to  allow  for  heater
expansion.

10.0

These heaters are intended to be installed in a maximum

40°C ambient temperature.

For  metal  sheathed  heaters,  insulation

contamination or moisture accumulation can

cause fault to the element sheath generating

arcing  and  releasing  molten  metal.  Install

proper  ground  fault  protection  to  prevent

personal injury and/or property damage.

FIG. 1  –  MOUNTING CLEARANCES

A

D

E

B

C

CCI Thermal Technologies Inc.  2721 Plymouth Drive, Oakville, ON L6H 5R5  Tel. (905) 829-4422  Fax (905) 829-4430

www.ccithermal.com

ISO 9001:2000

8.0 

For rod mounting ¼”-20 threaded rods of suitable length 

are to be installed in place of the eye bolts as in paragraph 7.0 
above.

9.0

  If  flush  mounting  on  a  non-combustible  surface,  be  sure 

to slot the mounting holes (5/16” x ½” hole) to allow for heater 
expansion.

10.0 

These heaters are intended to be installed in a maximum 

40°C ambient temperature.

For metal sheathed heaters, insulation 
contamination or moisture accumulation 
cancause fault to the element sheath 
generating arcing and releasing molten 
metal. Install proper ground fault protection 
to prevent personal injury and/or property 
damage.

Summary of Contents for OKB

Page 1: ...artz tube heating elements Use heaters with metal sheathed elements where there is heavy vibration or mechanical shock Quartz tube or quartz lamp elements are very fragile and require extreme care in handling Heaters utilizing quartz tubes or quartz lamps are unsuitable for applications in locations where the risk of heavy vibration or mechanical shock exists 3 0 To avoid damage in transit heaters...

Page 2: ...eathed element Use rigid conduit to ensure moisture protection When making wiring connections to the heater DO NOT pull power connection wires from end cover Pulling the wires could eliminate the expansion wire loop at the element end connection and may result in damage to wire insulation 15 0 Follow this procedure and Fig 2 when installing the tube or lamp 15 1 Disconnect power at source 15 2 Rem...

Page 3: ...om the date of installation The Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product s The Purchaser agrees that all warranty work required after the initial commissioning of the product will be provided only if the Company has been paid by the Purchaser in full accordance with the terms and conditions of the contract T...

Page 4: ...eau 1 OKB OKD OKH OKB OKD H K O L N C L S U A Du mur le plus près 24 610 mm 15 380mm 10 254mm B Du bout du radiateur au mur 24 610 mm 12 305mm 39 1000mm C Du plafond 24 610 mm 15 380mm 15 380mm D Du plancher 72 1830 mm 96 2400 mm E Entre les radiateurs 36 915 mm plafond en respectant les dégagements minimum requis indiqués au Tableau 1 8 0 Pour un montage avec des tiges filetées de longueurs adéqu...

Page 5: ...ur la procédure à suivre si l élément a moins de 1MΩ Ω Ω Ω Ω 16 0 Serrer la vis de réglage dans la pièce coulée d extrémité une extrémité seulement après avoir installé le radiateur et avoir réglé l angle d inclinaison horizontale Cette vis doit être serrée même si le radiateur n est pas incliné 17 0 Mettre l appareil sous tension à la tension indiquée sur la plaque signalétique et vérifier visuel...

Page 6: ... not intended for use in hazardous areas where flammable vapours gases or liquids or other combustibles are present Remember that objects placed under an infrared heater can take a while to reach stabilized temperatures If you are unsure of the suitability of the heater for the intended application check with the factory for recommendations Failure to comply can result in personal injury and or pr...

Page 7: ...ication inappropriée ou un défaut d alignement des pièces Aucune garantie ne s applique à la finition de peinture excepté dans le cas de défauts de fabrication apparen ts dans les 30 jours à compter de la date d installation La Société n assume ni n autorise aucune personne à assumer en son nom toute autre obligation ou responsabilité en rapport avec le les produit s L Acheteur accepte que tout tr...

Reviews: