4

Phone number field - 14 characters.

Some areas in Canada deliver only 7 digits.

(I.E. No area code is sent for calls from local

area code.) Private & Out-of-Area can be

sent in number & name fields.

Fig. 2a CallerID.com Format

Fig. 2a CallerID.com Format

(DIP Switch #7 set OFF)

(DIP Switch #7 set OFF)

Carriage Return

& Line Feed

2 Characters

Inbound/Outbound

& Start/End of call

Indicators. (Always

I & S for POS

series units.)

Checksum

Indicator

G (Good)

or B (Bad)

Date Field

(Month, Day)

Leading zeroes

are displayed.

Name field - 15 characters. No Padding

at the end of the Name Field

(Name sent in most areas in the US and

Canada) Private & Out-of-Area can

be sent in number & name fields.

Type of

ring and

# of rings.

(# of rings

always zero

for POS

series units.)

Time including

AM/PM Indicator.

Leading zeroes

are included.

Duration

of call in

seconds

(always

zero for

POS series

units.)

Line

Number

Preset

using

DIP

switches

1 - 3

Line Number

Preset using

DIP switches

1 - 3

R

C

F

L

03 I S 0000 G A0 09/26 11:28 AM 770-263-7111

CALLERID.COM

03 I S 0000 G A0 09/26 11:28 AM 770-263-7111

CALLERID.COM

NOTES: No dashes are inserted when the UK-BT/ETSI type Caller ID is captured (DIP switch 4 set ON).

All fields left justified. 1 space separates each field

Fig. 2b TCI Format

Fig. 2b TCI Format

(DIP switch #7 set ON)

(DIP switch #7 set ON)

R

C

F

L

03

9/26

11:28 AM

770-263-7111

CALLERID.COM

03

9/26

11:28 AM

770-263-7111

CALLERID.COM

Time

including

AM/PM

Indicator

Carriage Return

& Line Feed

2 Characters

11 Spaces

separate

these fields

Date Field

(Month, Day)

leading zeroes

are sent as spaces

NOTE: All fields right justified. 5 spaces separate each field except number and name fields.

Phone number field - 14 characters.

Some area in Canada deliver only 7 digit

numbers. (I.E. No area code is sent for calls

from local area code.) Private & Out-of-

Area sent in number field.

Name field - 15 characters. (Name sent

in most areas. This service referred to

as Caller ID Deluxe or Enhanced Caller

ID. Private & Out-of-Area codes are

shown in name field.

not

1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1

Summary of Contents for Whozz Calling? 4 POS Caller ID

Page 1: ...ng POS Caller ID Interface Unit Caller com ID ID CALLING WHOZZ POS Caller ID 4 CALLING WHOZZ POS Caller ID 8 Technical Manual for Whozz Calling POS Series 4 and 8 Line Units Belcore 202 USA DTMF Signaling Version ...

Page 2: ...computer through a serial port A serial printer connects using a null modem adapter or null modem cable A parallel printer requires a serial to parallel converter as well as a null modem adapter If connected to a computer the serial port must be free of COM Port and IRQ conflicts and dedicated to the monitoring unit The unit can work with any serial port regardless of the COM number and or IRQ it ...

Page 3: ... 4 Caller ID Signal Type Transmitted by TelCo Off FSK On DTMF 5 Baud rate Off 9600 On 1200 7 Output Format Off CallerID com On TCI 8 Unit model Off 8 line On 4 line 9 Not Connected 3 2 4 5 1 6 7 8 Device CID Signal Baud Rate Format 4 8 Line N C 1 3 4 5 7 8 9 Caller com ID ID Standard RS232 1200 or 9600 Baud Default is 9600 Baud 8 Bit 1 Stop No Parity Top jack connects to bottom jack of addional un...

Page 4: ...it 3 in the same manor CALLER ID DELIVERY TYPE Caller ID signaling is sent by the local phone company s central office in either of two different electronic formats Frequency Shift Keyed FSK signaling is used in the countries were newer central office equipment is installed such as the US Canada and Australia In countries or regions where older central office equipment is used Caller ID is deliver...

Page 5: ...G A0 09 26 11 28 AM 770 263 7111 CALLERID COM 03 I S 0000 G A0 09 26 11 28 AM 770 263 7111 CALLERID COM NOTES No dashes are inserted when the UK BT ETSI type Caller ID is captured DIP switch 4 set ON All fields left justified 1 space separates each field Fig 2b TCI Format Fig 2b TCI Format DIP switch 7 set ON DIP switch 7 set ON R C F L 03 9 26 11 28 AM 770 263 7111 CALLERID COM 03 9 26 11 28 AM 7...

Page 6: ...onnected to the back of the unit using modular jacks Input and output ports are provided for wiring systems using 2 wire RJ11 connections If the wiring coming into your building does not terminate in modular jacks contact your telephone vendor to add these modular connections CONNECTING DIRECTLY TO A PRINTER Printers have either a serial or parallel input Most newer printers use parallel connectio...

Page 7: ...pback Connector to the cable the other end is connected to the serial port on the PC 8 Type any character a If the character you typed shows on the screen the serial port is functioning properly the test is positive b If you do not see the character COM port and click OK c Select Call Connect and type any character again and repeat above as necessary 9 If you obtain a positive result close HyperTe...

Page 8: ...lephone Connections Whozz Calling POS 8 Line Model L1 L2 L5 L6 L3 L4 L7 L8 Even if your telephone system switch is Caller ID capable it will not pass analog Caller ID Therefore the POS series units must be connected to the phone lines coming into the building from the telephone company These lines are branched split or half tapped and connected to the input jacks of the monitoring unit If these li...

Page 9: ... repair facility or damage attributed to an act of God Lightning is considered an act of God CallerID com makes no other warranty either expressed or implied with respect to this product If a problem develops concerning this product contact CallerID com directly for a Return Material Authorization RMA FCC Information This unit is designed to conform to federal regulations and complies with Part 68...

Page 10: ...d acts as a control line When units are not transmitting data this line resides at 9 VDC Upon transmit the unit pulls this line to 9 VDC Other Whozz Calling units connected will detect this as a busy condition and will not transmit until the line returns to 9 VDC If connecting to a 25 pin serial port on the computer we suggest using a 9 to 25 pin serial adapter The pin outs on a 25 pin serial port...

Page 11: ...3107 D Medlock Bridge Road Norcross GA 30071 800 240 4637 770 263 7111 Caller com ID ID ...

Reviews: