The 2050 disabled toilet alarm kit is simple to 

install using 4-core alarm cable. The 12v PSU 

allows only low voltage inside the toilet area. 

Please follow the simple wiring diagram that 

can be downloaded from the web page.

Additional parts can be purchased for larger 

toilets.

Positioning the components

It is important to ensure that the positioning of 

the call/reset unit & the ceiling mounted pull 

switch cords are placed within easy reach of 

the user. A crucial point to remember is that 

many wheelchair users cannot turn round. 

Therefore do not fit the pull cords behind 

them. Ideally pull cords should be on a line in 

front of the toilet pan, see the illustration 

below.

For safety reasons the 240V/12 Volt 

transformer is supplied separately as this 

should be fitted above the ceiling tiles. This ensures 

that only low voltages are connected to the 

equipment in the toilet area.
Full installation information is supplied with the kit.
For multiple toilet sites central indicator panels may 

be required, such as Hospitals, Gyms, Schools, 

Hotels and Holiday Camps etc.

2050 Disabled Toilet Kit Wiring Overview

1114 Ceiling Mounted Pull Switch

1110 Over Door Indicator Lamp

ASSIST

RESET

12-24V PSU

2050 Call/Reset Unit

4 Core Alarm Cable

1117 Alarm indicator Panel For multi toilet 

installations

Relay Switched 

output for third party 

systems

Engraved name 

inserts can be fitted

Digital panels also 

avalible

 

 

PSU

PAN IC

PAN IC