IMPORTANT SAFETY INFORMATION

-INSTALLATION AND PREPARATION SAFETY GUIDELINES

1.

Before installing this outdoor firepit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

must be maintained when you install this outdoor firepit.

THERE

MUST BE AT LEAST 24”

from the side of appliance to any combustible materials.

2. The outdoor firepit is for

outdoor

use only.

DO NOT

install or use this appliance inside a building,

garage, or any other enclosed area including recreational vehicles and/or boats.

This unit must

be installed in such a manner that proper air ventilation is maintained without obstruction.
At all times, and during all weather conditions.

3.

CHECK GAS TYPE

(natural gas or propane): The gas supply you intend to use may not be the

same as that stated on your outdoor firepit rating plate.

THIS FIREPIT IS CONSTRUCTED FOR

USE WITH PROPANE GAS.

If the gas supply is different, or if

you wish to change to natural

gas, you MUST have the firepit converted (method described on page 8) to the gas type
you intend to use, by a qualified, professional installer.

If you are unsure, contact your dealer

for assistance.

4. DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR

EXCEEDS THE MAXIMUM.

5. FOR NATURAL GAS:

The minimum inlet gas supply pressure for purposes of input adjustment

is

5 inches

water column and maximum inlet gas supply pressure is

10 inches

water column.

FOR PROPANE:

The minimum inlet gas supply pressure for purposes of input adjustment is

8

inches

water column and the maximum inlet gas supply pressure is

13 inches

water column.

6. Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate

(BTU/hr). Undue pressure loss will occur if the pipe is too small or the run is too long

7. For installations at elevations above 2,000 ft., contact your local dealer or gas supplier before

installing as input ratings should be reduced approximately 4% for each 1,000 ft. above sea level.
Refer to the National Fuel Gas Code.

Contact the factory for the required orifice

.

8. The outdoor firepit and its main gas valve must be disconnected from the gas supply piping

system during any pressure testing of that system at test pressures in excess of ½ psig. This is
accomplished by closing the gas supply line valve, as required by NFPA 54, section 5-54.

9. The outdoor firepit must be isolated from the gas supply piping system by closing its equipment

shut-off valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than ½ psig.

10. INSTALLER NOTE: This unit should be installed so that it can be removed at a later date

for service.

11. GAS SUPPLY PLUMBING REQUIREMENTS

Apply only joint compounds that are resistant to all

gasses on all male pipe fittings.

12. DO NOT BURN SOLID FUELS OF ANY KIND IN THIS APPLIANCE.

Summary of Contents for OUTDOOR LIVING REDEFINED OUTDOOR FIREPIT

Page 1: ...appliance is for connection to a fixed piping system the installation must conform with local codes or in the absence of local codes the National fuel Gas Code ANSI Z223 1 NFPA 54 or International Fuel Gas Code Installer Leave This Manual with Consumer Consumer Save this Manual for Future Reference WARNING improper installation adjustment alteration service or maintenance can cause injury or prope...

Page 2: ...ETY INFORMATION READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIREPIT If not installed and used correctly per these instructions this product can cause serious injury CAUTION INSTALLATION MODIFICATION AND REPAIR MUST BE DONE BY A QUALIFIED PROFESSIONAL INSTALLER Be sure you understand all safety precautions and warnings contained in this manual 1 CHECK STATE AND LOCAL CODES TO DETER...

Page 3: ...nt is 5 inches water column and maximum inlet gas supply pressure is 10 inches water column FOR PROPANE The minimum inlet gas supply pressure for purposes of input adjustment is 8 inches water column and the maximum inlet gas supply pressure is 13 inches water column 6 Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue pressure loss will occur i...

Page 4: ...f Dangerous Goods and Commission CAN CSA B399 BEFORE INSTALLATION BE SURE THE PROPANE TANK IS TURNED OFF To connect to the propane gas tank attach the black hose with regulator and tighten down the connector see photos below Follow all instructions and safety warnings supplied with the propane tank Propane cylinder must have a listed over filling protection device Turn on the gas to the burner sys...

Page 5: ...shipping damage If any parts are missing or damaged call your dealer Do not attempt to install the appliance unless all parts are in good condition B Correct installation is crucial to safe performance of your Outdoor Fire Pit C Due to high temperatures the Fire must be located out of traffic areas and away from combustibles LAVA GRANULES LOG PARTS LIST Replacement parts available from your local ...

Page 6: ...anules into the Outdoor Firepit so that it completely covers the burner See figures 1 and 2 2 Place the largest log diagonally centered over the burner See figure 3 3 Place the other logs as desired using the first log figure 3 as a support to lean the other logs against See figure 4 ...

Page 7: ...SOME TIME AFTER USE YOU MUST MAINTAIN THE LOG LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR LOG SET IF YOU NEED TO REPOSITION ANY LOG TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW LOGS ADEQUATE TIME TO COOL BEFORE HANDLING FIGURE 3 FIGURE 4 ...

Page 8: ...bag s of ARCTIC FLAME GLASS into the Outdoor Firepit so that it completely covers the burner See figures 1a and 2b 2 Place all of the enclosed ARCTIC FLAME GLASS into the burner Not using all of the glass may result in a low flame Figure 1a Figure 2b ...

Page 9: ...hnician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Firepit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMATION ABOVE 1 Turn the manual gas control slig...

Page 10: ...T hang clothing or any flammable material on or near your Firepit Matches paper garbage or any other material must not be thrown on top of the logs burner or into the flame I DO NOT use your Firepit if any part of it has been under water Immediately call a qualified service technician to inspect the set and to replace any part of the control system and any gas control which has been under water J ...

Page 11: ...nd the point of contact between the cylinder and the retention means 2 The LP gas supply cylinder to be used must be constructed and marked in accordance with the U S Department of Transportation D O T Specifications for LP Gas Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable 3 The LP cylinder must be provided with a listed overfilling pre...

Page 12: ...your fire ring or enclosure 4 Carefully detach the connector hose attached to the orifice holder and unscrew the orifice holder from the burner pipe 5 Remove the orifice from the holder and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 6 If you are converting from natural gas NG to propane LP gas slide the air shutter so that the air intake hole...

Page 13: ...Outdoor Concepts Parts List Burner Pan Part 804 Orifice with Air Mixer Part 803 Connector Hose Part 812 Valve Part 805 Nipple Part 809 Brass Jam Nut Part 811 Gas Knob Part 807 Hose and Regulator Assembly Part 812 ...

Page 14: ...Replacement Parts are Available from Your Dealer ...

Page 15: ...sland 7310 Palm Chat 7140 Monterey Coffee Table 7320 Palm Dining 7330 Palm Bar 7410 Tradewinds Chat 7420 Tradewinds Dining 7430 Tradewinds Bar 7520 La Jolla 7550 La Paz 7610 El Paseo 7611 Rodeo Chat 7651 Rodeo Balcony 17671 Irvine Blvd Suite 108 Tustin CA 92780 Toll Free 877 274 6773 Fax 877 274 0017 www californiaoutdoorconcepts com Use your smart phone QR code reader to view Follow us on Faceboo...

Page 16: ...egulator the appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at pressures in excess of psi 3 5 kPa The appliance must be isolated from gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas line at test pressures equal to or less than psi 3 5 kPa LP Gas...

Reviews: