8508_ii_190227
Pg 2
INSTALLING ESCUTCHEON
•
Insert O-RING (
11f
) into handle BASE (
11e
), place
COINED RING (
11d
) on handle BASE (
11e
),
position handle RISER (
11c
) on COINED RING
(
11d
), fit WASHER (
11b
) to ESCUTCHEON TOP
(
11a
), place ESCUTCHEON TOP (
11a
) onto
RISER (
11c
)
NOTE:
Confirm orientation of RISER (
11c
); hash marks at bottom as
shown
•
Place ESCUTCHEON ASSEMBLY (
11
) onto VALVE
(
6
) and secure to tub/deck surface by tightening
ESCUTCHEON TOP (
11a
)
•
Use a ruler or straight edge to align the spout base
and escutcheons of the faucet as shown
•
After alignment retighten ESCUTCHEON TOP
(
11a
) and spout NUT (
4
)
NOTE:
Return to Section 2 if valve is not aligned properly
INSTALLING HANDLE
•
Slide HANDLE (
12
) down onto and engage valve
STEM (
6a
)
•
Tighten handle NUT (
12a
)
INSTALLING SUPPLY LINES
•
Must use rigid copper piping (not flex) for all
connections between spout and valves
•
California Faucets recommends that all installation
types have access panel(s) to allow for maintenance
and/or service
Disclaimer:
To conform to many local codes and/or ordinances, it
may be required that California Faucets Roman Tub sets be installed in
conjunction with an ASSE 1070 approved tempering valve to reduce
hot water supply to a safe temperature.
Important:
the INSTALLER is responsible to check local codes
and/or ordinances, to confirm and verify proper maximum hot water
temperature settings for all products installed.
Warning:
Water temperatures in excess of 110º F (43ºC) are
dangerous and may cause severe scalding and injury.
3
4
5
12
12
12
12a
12a
12a
6a
6
11f
11e
11d
11c
11b
11a
Hot
Supply
Cold
Supply
With ASSE 1070
tempering valve
calfaucets.com
5271 Argosy Ave. Huntington Beach, CA 92649 800-822-8855