California Faucets Solimar CF-TO-V7002-9 Installation Instructions Download Page 2

CF-TO-V7002-9_ii_160720 

 

 

 

 

Pg 2 

ALIGN & TRIM VALVE STEM 

 

Remove MUDGUARD (1b) from VALVE (1)

 

 

 

To  obtain  proper  HANDLE  (11)  alignment  it  may 
be  necessary  to  re-align  cartridge  STEM  (1a);  to 
align STEM (1a), slightly loosen the cartridge  NUT 

(1c),  place  HANDLE  (11)  on  STEM  (1a)  and 
TIGHTEN  in  CW  direction  until  desired 
alignment is achieved; retighten cartridge NUT (1c

to factory torque setting of 14 ft-lbs.  

WARNING:    Cartridge  NUT  (1c)  MUST  be  properly  torqued  to 

prevent possible failure and/or water damage 

 

Unscrew ALL-THREAD (9) from valve STEM (1a)

 

 

 

Cut STEM (1a) 1-3/8” from finished wall surface 

 

Reattach  ALL-THREAD  (9)  onto  valve  STEM  (1a), 
using  a  marking  device  (e.g.  pencil  or  marker) 

indicate a distance of ¾” from finished wall on ALL-
THREAD (9); remove ALL-THREAD (9) and cut off 
excess  ALL-THREAD  (9)  at  indicated  mark  & 
reattach ALL-THREAD (9) onto valve STEM (1a)

 

– 

repeat on other side 

IMPORTANT:  To prevent HANDLE (11) rotation during operation 
of  faucet  set  LOCK-NUT  (8)  MUST  be  placed  on  both  ALL-

THREAD (9) of VALVE (1

 

Place  LOCK-NUT  (8)  onto  ALL-THREAD  (9)  and 
tighten against cartridge NUT (1c) to prevent ALL-
THREAD  (9)  from  rotating  while  operating 
HANDLE (11) – repeat on other side 

 

 

INSTALLING ESCUTCHEON

 

 

Insert  O-RING  (4)  into  ESCUTCHEON  (5)  and 
place onto ALL-THREAD (9)

 

 

 

Secure  ESCUTCHEON  (5)  onto  wall  by  tightening 
lock NUT (10

 

To  align  ESCUTCHEONS  (5),  use  a  ruler  or 
straight  edge  to  align  the  spout  and  handle 
escutcheons of the faucet as shown; after alignment 
retighten lock NUTS (10)  

 

 

INSTALLING HANDLE

 

 

Loosen SETSCREW (11a) from POST (11c)

 

 

IMPORTANT:    Handle  BLADE  (11b)  shall  be  aligned  with  wider 

portion of handle POST (11c)

 

 

 

Slide  HANDLE  (11)  down  onto  and  engage  valve 
STEM (1a)

 

 

 

Handle  POST  (11c)  shall  completely  cover  lock 
NUT (10) and seat against ESCUTCHEON (5

 

Tighten  SETSCREW  (11a)  and  rotate  handle 
BLADE (11b) to check operation, open position is 

when BLADE (11b) is rotated upward – repeat on 
other side  

 

 
 

1-3/8” 

californiafaucets.com    5271 Argosy Ave. Huntington Beach, CA 92649    800-822-8855

 

13/16” 

hex 

3/4” 

11/16” 

hex 

Reviews: