California Faucets 7208 Installation Instructions Download Page 2

"A"

Escutcheon

Sink/

Countertop

Spacer Cup

Fiber Washer

Bottom Nut

Valve

OUTLET

 

INLET

 

P2

Install valve bodies 

(See Fig. 1 & 3)

:

7202 Series 

"A" = 3/4"

7302 Series 

"A" = 1"

Fig. 3

NOTE:

 Hot & cold valves are labeled: 

RED

 = hot & 

BLUE

 = cold.

-Remove top nut and discard.

-Turn bottom nut with fiber washer down the valve until it stops.

-Place spacer cup onto valve oriented correctly as shown.

-Insert valve through hole from below.

-Attach and thread escutcheon onto threads below stem and

 adjust valve to scheduled height "A".

-Place handle onto stem allowing minimal gap between escutcheon and 

 handle.  Tighten setscrews with Allen key provided.

-Align handle in desired position and tighten the bottom nut to secure valve.

 

NOTE:  Align square escutcheon on 7202 Series prior to securing valve.

        Piping:

  

3

2

 

-Use rigid copper piping (not included) to connect hot & cold valves to tee & water supply 

(See Fig. 1).

Flexible hoses are not recommended for the following reasons:

   1.  Hoses may be inaccessible and require occasional replacement;

   2.  Some trim installations require escutcheon to hold valve in place.

WARNING:  To prevent damage to valve all soldering shall be performed before attaching fitting directly to valve.

                    Any additional soldering should be performed at least 6" away from valve ports. 

RT_7208_ii_101220