California Air Tools 5510SE Owner'S Manual Download Page 12

12

Customer Support: 1-866-409-4581

AIR COMPRESSOR

MAINTeNANCe

draining the air tank

The frequency at which you should drain the air tank depends on

the environmental conditions and the amount of operating time

logged. The average draining frequency is every 2 to 3 days.

1.

Place the air compressor above a container capable of holding

water. 

2.

With compressed air in the air tank, slowly turn the drain valve

knob to the forward (open) or straight position.

The water in the air tank will drain out. 

3.

After all of the accumulated water has drained out, turn the

drain valve knob to the closed or left position in order to avoid

leakage.

cleaning or changing the air filter

The air filter is designed to reduce noise and  help prevent

particulates in the air from entering and damaging the air

compressor.
After being used for a period of time, the air filter will become

clogged. This will reduce the air intake capabilities of the air

compressor, reducing performance. Therefore, the air filter must

be cleaned or replaced regularly.

1.

Open the lid on the air filter, then remove the air filter element.

2.

To clean the element blow off or brush off the dirt and dust.

3.

If clogged, replace with a new air filter.

testing for Leaks

Make sure all connections are tight. do not overtighten.
A small leak in any hose or pipe connection will reduce the air

compressor's performance.
To test for small leaks, spray a small amount of soapy water on

the area suspected of leaking. If the soap bubbles, replace the

broken part.

cleaning

Clean items with a soft brush, or wipe with a moistened cloth

using a biodegradable solvent.
do not use flammable liquids such as gasoline or alcohol. Always

keep parts clean from dirt and dust for better performance.

pressure Switch

The pressure switch is factory pre-set to shut off at between
115 - 120  PSI and to re-start at between 85 -90 PSI

STORAge

before storing for a prolonged period of time:

1.

Turn off the power supply.

2.

disconnect the power cord from the power supply.

3.

Pull the relief valve and release all the pressure from the air

tank.

4.

Clean the air compressor to remove all dirt and dust.

5.

Cover the air compressor with a cover to protect the unit from

dust and moisture.

6.

do not stack or store any items on top of or around the air

compressor. damage could occur.

Summary of Contents for 5510SE

Page 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 5510SE 1 0 HP 3 10 CFM 40 PSI 2 20 CFM 90 PSI 5 5 gALLOn STEEL TAnk WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581...

Page 2: ...________________12 draining the air tank ___________________________12 changing the air filter__________________________12 testing for Leaks ______________________________12 pressure Switch __________...

Page 3: ...compressor do not return your air compressor for service or parts to the store dealer where purchased IMPORTANT SAFeTy INSTRuCTIONS Safety messages Signal Words DANGER Moving parts can cause severe t...

Page 4: ...the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are c...

Page 5: ...extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and p...

Page 6: ...e labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR...

Page 8: ...back of the air compressor Screw the air filter into the motor head port that is located under the Plastic head Cover Install the Wheel kit 1 Slide Washer 61 through bolt 60 2 Slide bolt 60 through W...

Page 9: ...or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is no...

Page 10: ...ar system making the piston move reciprocally The piston is made from a high temperature resistant and abrasion resistant nonmetallic material and is able to function without lubrication for a long ti...

Page 11: ...air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on t...

Page 12: ...he air filter then remove the air filter element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter testing for Leaks Make sure all connections a...

Page 13: ...ndings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltag...

Page 14: ...rth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gau...

Page 15: ...ic legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusiv...

Page 16: ...by California Air Tools Inc 9 Acts of god The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California A...

Page 17: ...tion date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number...

Reviews: